AR-BC320 OTHERS 15 - 6
44
4
Image density correction
(Process control) target
level setup
A: Color image density sensor
adjustment target value
1 to 255
108
EEPROM
(PCU PWB)
B: Black image density sensor
adjustment target value
1 to 255
201
C: Initial current level in color image
density sensor adjustment
1 to 255
51
D: Initial current level in black image
density sensor adjustment
1 to 255
51
E: Allowable error level in adjustments
1 to 255
2
F: Error judgment level for the belt
surface detection level difference
1 to 255
255
G: Set value (color) of the developing
basis correction start voltage difference
in high density image correction
0 to 255
50
H: Set value (black) of the developing
basis correction start voltage difference
in high density image correction
0 to 255
75
I: Patch forming developing bias
voltage interval (voltage difference) in
high density image correction
1 to 255
50
J: Base target density level (Y) in high
density image correction
1 to 255
108
K: Base target density level (M) in high
density image correction
1 to 255
125
L: Base target density level (C) in high
density image correction
1 to 255
109
M: Base target density level (K) in high
density image correction
1 to 255
22
N: Error judgment level for belt surface
detection level difference
1 to 255
29
O: Adjustment target value (Color
image density sensor) when adjusting
the primary LED current value by using
the calibration plate in SIM44-36.
1 to 255
110
P: In SIM44-36, the toner patch density
is read by three kinds of LED currents
with the primary LED current
adjustment value as the center value in
order to obtain PCS C LED ADJ value.
This is the deflection range of the
current value in the above case.
1 to 255
10
13
Color image density
sensor sense level
adjustment
LED current adjustment target value
1 to 255
108
EEPROM
(PCU PWB)
Dark voltage level
0 to 255
0
Current adjustment value
1 to 255
51
21
Half tone image
correction initial setup
Setup data
0 to 255
–
The setup data
cannot be
entered directly
EEPROM
(ICU PWB)
Simulation
Code
Content/Item
Set range
Default
NOTE
Data store
location
Main Sub.