AR-BC320 SIMULATION 9 - 23
(Set value)
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
(Set value)
Color
Item
Operation mode
Adjustment value
Developing bias voltage
Monitor (High voltage PWB)
Pin
No.
Actual
voltage
Adjustment
range
Specified
value
(Default)
Monitor voltage
(Specified
value)
Connector
K
A: HIGH SPEED
High speed (140mm/s) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
– 215v
B: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
– 215v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
0 – 585
185
3.46 ± 0.1V
CNMONK
3
– 185v
C
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
1
– 265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
0 – 585
235
4.75 ± 0.1V
CNMON
1
– 235v
M
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
5
– 265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
0 – 585
235
4.75 ± 0.1V
CNMON
5
– 235v
Y
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
0 – 585
240
4.75 ± 0.1V
CNMON
9
– 240v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
0 – 585
210
3.78 ± 0.1V
CNMON
9
– 210v
8
-2
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of each print
mode main charger grid voltage and the control
circuit.
Section
Process
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(The charging/grid output voltage in each print
mode can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and
[Y] keys.
2. Select the print mode with [
↑
] key and [
↓
] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Color
Item Operation
mode
Adjustment value
Main charger grid voltage
Monitor (High voltage PWB)
Pin
No.
Actual
voltage
Adjustment
range
Specified
value
(Default)
Monitor voltage
(Specified
value)
Connector
K
A: HIGH SPEED
High speed (140mm/s) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
B: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMONK
1
–590v
C
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
3
–590v
M
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
7
–590v
Y
A: MIDDLE SPEED Middle speed (117mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
180 – 700
590
50.6 ± 0.2v
CNMON
11
–590v
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...