AR-BC320 TROUBLESHOOTING 11 - 4
Main
code
Sub
code
Title
Shading trouble (Black correction)
E7
10
Display
Lamp/Message
Phenomenon Detail
CCD black reading level
abnormality when the copy
lamp is off.
Section
CCD unit
Case 1
Cause
Improper installation of the
flat cable to the CCD unit.
Check &
Remedy
Check installation of the
flat cable to the CCD unit.
Case 2
Cause
CCD unit abnormality
Check &
Remedy
Check the CCD unit.
Case 3
Cause
MFP PWB abnormality
Check &
Remedy
Check the MFP PWB.
Main
code
Sub
code
Title
Shading trouble (White correction)
E7
11
Display
Lamp/Message
Phenomenon Detail
CCD white reading level
abnormality when the copy
lamp is off.
Section
CCD unit
Case 1
Cause
Improper installation of the
flat cable to the CCD unit.
Check &
Remedy
Check installation of the
flat cable to the CCD unit.
Case 2
Cause
Dirt on the mirror, the lens,
or the reference white plate.
Check &
Remedy
Clean the mirror, the lens,
or the reference white
plate.
Case 3
Cause
CCD unit abnormality
Check &
Remedy
Check the CCD unit.
Case 4
Cause
MFP PWB abnormality
Check &
Remedy
Check the MFP PWB.
Main
code
Sub
code
Title
LED controller initial trouble
(Black)
E7
20
Display
Lamp/Message
Phenomenon Detail
The initial process of the
LED controller cannot be
completed properly.
Section
LED/ICU PWB
Case 1
Cause
Disconnection of the LED
head connector.
Check &
Remedy
Check connection of the
LED head connector.
Case 2
Cause
Disconnection of the
harness inside the LED
head.
Check &
Remedy
Replace the LED head
unit.
Case 3
Cause
ICU PWB abnormality
Check &
Remedy
Replace the ICU PWB.
Main
code
Sub
code
Title
LED controller initial trouble
(Cyan)
E7
21
Display
Lamp/Message
Phenomenon Detail
The initial process of the
LED controller cannot be
completed properly.
Section
LED/ICU PWB
Case 1
Cause
Disconnection of the LED
head connector.
Check &
Remedy
Check connection of the
LED head connector
Case 2
Cause
Disconnection of the
harness inside the LED
head.
Check &
Remedy
Replace the LED head
unit.
Case 3
Cause
ICU PWB abnormality
Check &
Remedy
Replace the ICU PWB.
Main
code
Sub
code
Title
LED controller initial trouble
(Magenta)
E7
22
Display
Lamp/Message
Phenomenon Detail
The initial process of the
LED controller cannot be
completed properly.
Section
LED/ICU PWB
Case 1
Cause
Disconnection of the LED
head connector.
Check &
Remedy
Check connection of the
LED head connector
Case 2
Cause
Disconnection of the
harness inside the LED
head.
Check &
Remedy
Replace the LED head
unit.
Case 3
Cause
ICU PWB abnormality
Check &
Remedy
Replace the ICU PWB.
Main
code
Sub
code
Title
LED controller initial trouble
(Yellow)
E7
23
Display
Lamp/Message
Phenomenon Detail
The initial process of the
LED controller cannot be
completed properly.
Section
LED/ICU PWB
Case 1
Cause
Disconnection of the LED
head connector
Check &
Remedy
Check connection of the
LED head connector.
Case 2
Cause
Disconnection of the
harness inside the LED
head.
Check &
Remedy
Replace the LED head
unit.
Case 3
Cause
ICU PWB abnormality
Check &
Remedy
Replace the ICU PWB.