AR-BC320 OTHERS 15 - 4
21
1
Maintenance cycle setup Maintenance timing (Print quantity)
0 to 6
4
0: 5K
1: 10K
2: 15K
3: 40K
4: 50K
5. 100K
6. FREE
EEPROM
(PCU PWB)
BELT
50K/100K
100K
FUSER
50K/100K
100K
26
2
Tray/size setup
LCC paper size setup
1 to 2
1
EEPROM
(PCU PWB)
8.5" x 13" paper size detection
0/1
0
Manual paper feed paper display type
0 to 2
0
3
Auditor mode setup
Built-in auditor mode
1 to 5
1
1. P10
2. AR-EC1
(Japan only)
3. MODE1 to 3
EEPROM
(PCU PWB)
Card counter mode
Coin vendor mode 1
Coin vendor mode 2
Coin vendor mode 3
5
Counter mode setup
A: Total counter (B/W)
1/2
2
EEPROM
(PCU PWB)
B: Total counter (Color)
1/2
2
C: Mantenance (B/W)
1/2
2
D: Mantenance (Color)
1/2
2
6
Destination setup
Destination
1 to 10
1
EEPROM
(PCU PWB)
10
Trial mode of the
network scanner setup.
A: Trial mode setting
0/1
0
18
Toner save mode setup
A: Copy mode toner save mode inhibit
0/1
0
EEPROM
(PCU PWB)
B: FAX mode toner save mode inhibit
0/1
0
C: Printer mode toner save mode inhibit
0/1
0
35
Trouble memory mode
setup
A: Trouble memory mode
0/1
0
EEPROM
(PCU PWB)
38
Print stop setup when
the engine life is over
A: Continue/Stop
0/1
0
EEPROM
(PCU PWB)
52
Non-print paper count up
setup
A: Count up YES/NO setup
0/1
1
EEPROM
(PCU PWB)
53
User auto color
calibration (Copy color
balance/density auto
adjustment) YES/NO
setup
A. YES/NO
0/1
1
EEPROM
(PCU PWB)
27
1
U7-00 detection setup
A: PC/MODEM communication trouble
(U7-00) detectionYES/NO
0/1
0
EEPROM
(PCU PWB)
5
Tag number setup
Tag number set value
Input value
(max. 8
digits)
EEPROM
(PCU PWB)
40
2
Manual feed tray paper
width detection level
adjustment
1. Max. position
0 to
0xFFFF
241
The adjustment
value cannot be
entered directly.
EEPROM
(PCU PWB)
2. P1 (A4) position
0 to
0xFFFF
231
3. P2 (A4R) position
0 to
0xFFFF
140
4. Min. position
0 to
0xFFFF
19
7
Manual feed tray paper
detection level
adjustment
A: Max. position
0 to 255
241
This simulation
is not used
normally. Use
SIM40-02
instead.
B: P1 position
0 to 255
231
C: P2 position
0 to 255
140
D: Min. position
0 to 255
19
Simulation
Code
Content/Item
Set range
Default
NOTE
Data store
location
Main Sub.
Summary of Contents for AR-BC320