AR-BC320 SIMULATION 9 - 44
∗
This simulation is not normally used. Adjustment is made with
SIM 40-02.
(Set range)
(Sensors to be detected)
2. Set an A3 paper (11" x 17") and press the [EXECUTE] key.
The sensor level setting with document is performed.
3. The message of completion of the adjustment is displayed.
∗
The value in [ ] shown at the right of each sensor name is the
threshold value.
PD1 – PD7 light receiving (A/D value) and threshold value (A/D
value) range is 1 – 255. The default of the threshold value is 128.
40
-7
Purpose
Setting
Function
(Purpose)
Used to enter the adjustment value of the manual
paper feed tray paper width detector detection level.
(Setting)
Section
Paper feed
Item
Specifications
Operation/
Procedure
1. Select the item (setting) to be entered with the
scroll key.
2. Enter the adjustment value with the 10-key pad.
3. Press the [OK] key.
Item
Set range
Default
A
MAX POSITION
0 – 255
241
B
P1 POSITION
0 – 255
231
C
P2 POSITION
0 – 255
140
D
MIN POSITION
0 – 255
19
41
41
-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size
sensor and the related circuit. (The operation of the
document size sensor can be monitored with the
LCD display.)
Section
Others
Item
Operation
Operation/
Procedure
The active sensors and detectors are highlighted.
OCSW
OC cover open/close
detection
Open: Highlighted,
Close: Normal
PD1
Document sensor 1
No document (not detected):
Normal
Document loaded (detected):
Highlighted
PD2
Document sensor 2
PD3
Document sensor 3
PD4
Document sensor 4
PD5
Document sensor 5
PD6
Document sensor 6
PD7
Document sensor 7
41
-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document size sensor detection
level.
Section
Others
Item
Operation
Operation/
Procedure
1. Open the document table, and press the
[EXECUTE] key without document on the
document table. The sensor level setting with no
document on the table is performed.
41
-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size
sensor and the related circuit. (The document size
sensor output level can be monitored with the LCD
display.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor (PD1 –
PD7) is displayed in real time.
43
43
-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each
operation mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode
with the scroll key.