AR-BC320 SIMULATION 9 - 47
2. If the operation is normally completed, COMPLETE is
displayed and the correction result becomes valid.
If the operation is not normally completed, ERROPR is highlighted
and the detail of the trouble is displayed.
The detail of correction can be checked with SIM 44-9 and SIM
44-12.
(Result/Detail messages list)
2. [CPY/PRN] key selected: Process control mode is displayed.
[CAD] key selected: Drawing mode is displayed. (Printer, etc.)
[OTHER] key selected: The environment area and the number
of execution of process control are displayed.
(Displayed items)
Operation/
Procedure
1. Press the [EXECUTE] key, and the image
forming section correction is started.
Result display
Content
COMPLETE
Correction is normally completed.
ERROR
An error occurred during correction. (The
previous correction result is maintained.)
COMPULSORY
INTERRUPTION
Compulsory interruption
Error display
Content
COLOR_SENSOR_
ADJUSTMENT_ERROR
Color image density sensor
adjustment error
BLACK_GAIN_
ADJUSTMENT_ERROR
Black image density sensor
gain adjustment error
BLACK_SENSOR_
ADJUSTMENT_ERROR
Black image density sensor
adjustment error
BLACK_PROCON_ERROR
High-density image density
correction (process
correction) error (K)
CYAN_PROCON_ERROR
High-density image density
correction (process
correction) error (C)
MAGENTA_PROCON_ERROR
High-density image density
correction (process
correction) error (M)
YELLOW_PROCON_ERROR
High-density image density
correction (process
correction) error (Y)
CONNECTION_ERROR
Sensor-PCU PWB
communication trouble
44
-9
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to check the data related to the image forming
section correction (the corrected main charger grid
voltage in each print mode, the developing bias
voltage, etc.). (Used to check that correction is
performed normally or not.)
Section
Process (Photoconductor, developing, transfer,
cleaning)
Item
Data
Operation data (Machine conditions)
Operation/
Procedure
1. By scrolling with the scroll key, each data of the
image forming section correction result. can be
checked.
Display
Content
P (PROCON
MODE)
Main charger grid voltage/developing bias
voltage by high density image correction
(Y, M, C, K)
N (NORMAL
MODE (MIDDLE)
Actual main charger grid voltage/developing
bias voltage (Normal, medium speed mode)
(Y, M, C, K)
N (NORMAL
MODE (LOW)
Actual main charger grid voltage/developing
bias voltage (Normal, low speed mode) (Y,
M, C, K)
N (NORMAL
MODE (HIGH)
Actual main charger grid voltage/developing
bias voltage (Normal, high-speed mode) (K)
TS (TONER SAVE
MODE)
Actual main charger grid voltage /
Developing bias voltage (toner save high/
medium/low speed mode) (K)
D (DRAWING
MODE (MIDDLE)
Actual main charger grid voltage/developing
bias voltage (Drawing, medium speed
mode) (Y, M, C, K)
D (DRAWING
MODE (LOW)
Actual main charger grid voltage /
Developing bias voltage (drawing, low
speed mode) (YMCK)
TEMPERATURE
AREA
Temperature area
TEMPERATURE
Temperature (HEX value)
HUMIDITY AREA
Humidity
HUMIDITY
Humidity (HEX value)
MD X STEP
(M/L/H)
Photoconductor drum membrane decrease
correction step (Max. 4 steps) /Correction
voltage
CONVERSION
Discrimination of Sharp version and other
company version of toner cartridge
(0: SHARP, 1: Other company)
DESTINATION
Destination of toner cartridge stored in the
machine memory
MODEL TYPE
Toner cartridge application model (DM/AR)
CRUM
DESTINATION (X)
Toner cartridge destination
DV X STEP (X)
Developing bias voltage correction step
(corretion voltage) for toner cartridge life
HV
Number of corrections of high density
image density
HT
Number of corrections of half-tone image
density
44
-12
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to check the sampling toner image patch
density data in the image forming section correction
(high-density correction) (process correction). This
simulation allows to check if the correction
operation is performed normally.)
Section
Process (Photoconductor, developing, transfer,
cleaning)
Item
Data
Operation data (Machine conditions)
Operation/
Procedure
The [TARGET] key and the [PATCH] key are used
to select the display of the correction target level of
each color and the toner image patch density
sampling data.