AR-BC320 TROUBLESHOOTING 11 - 16
Main
code
Sub
code
Title
Half-tone process control 2nd
batch trouble (Cyan)
F2
85
Display
Lamp/Message
Phenomenon Detail
Second step operation
error during half-tone
process control
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in the
gain adjustment of SIM 44-
2:
1. Disconnection of the
harness between the
PCU PWB and the
image density sensor.
2. Image density sensor
dirt/trouble
Check &
Remedy
1. Check connection of the
harness between the
PCU PWB and the
image density sensor.
2. Clean/replace the
image density sensor.
Case 2
Cause
When SIM 44-2 gain
adjustment is completed:
Insufficient cleaning of the
transfer belt, calibration
plate solenoid operation
trouble
Check &
Remedy
Check the drum surface
and the belt surface.
Main
code
Sub
code
Title
Half-tone process control 2nd
batch trouble (Magenta)
F2
86
Display
Lamp/Message
Phenomenon Detail
Second step operation
error during half-tone
process control
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in the
gain adjustment of SIM 44-
2:
1. Disconnection of the
harness between the
PCU PWB and the
image density sensor.
2. Image density sensor
dirt/trouble
Check &
Remedy
1. Check connection of the
harness between the
PCU PWB and the
image density sensor.
2. Clean/replace the
image density sensor.
Case 2
Cause
When SIM 44-2 gain
adjustment is completed:
Insufficient cleaning of the
transfer belt, calibration
plate solenoid operation
trouble
Check &
Remedy
Check the drum surface
and the belt surface.
Main
code
Sub
code
Title
Half-tone process control 2nd
batch trouble (Yellow)
F2
87
Display
Lamp/Message
Phenomenon Detail
Second step operation
error during half-tone
process control
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in the
gain adjustment of SIM 44-
2:
1. Disconnection of the
harness between the
PCU PWB and the
image density sensor.
2. Image density sensor
dirt/trouble
Check &
Remedy
1. Check connection of the
harness between the
PCU PWB and the
image density sensor.
2. Clean/replace the
image density sensor.
Case 2
Cause
When SIM 44-2 gain
adjustment is completed:
Insufficient cleaning of the
transfer belt, calibration
plate solenoid operation
trouble
Check &
Remedy
Check the drum surface
and the belt surface.
Main
code
Sub
code
Title
Half-tone process limit error
F2
90
Display
Lamp/Message
Phenomenon Detail
The difference between
the correction value after
execution of half-tone
process control and the
previous correction value
exceeds the specified max.
value of each color.
<The error is recorded in
the trouble history, but F2
trouble is not indicated on
the display and the
previous correction value
is remained.>
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in the
gain adjustment of SIM 44-
2:
1. Disconnection of the
harness between the
PCU PWB and the
image density sensor.
2. Image density sensor
dirt/trouble
Check &
Remedy
1. Check connection of the
harness between the
PCU PWB and the
image density sensor.
2. Clean/replace the
image density sensor.