AR-BC320 SIMULATION 9 - 67
(Items to be set)
1. Select the color to be set with the color keys (CMY).
2. The display page can be shifted with the scroll key.
TRAYVOLMAX Tray paper
max. width
detection
After selecting
TARYVOLMAX, set the tray
document guide to the
maximum width position, and
press the [EXECUTE] key.
TRAYVOLB5
Tray B5 width
detection
After selecting TARYVOLB5,
set the tray document guide
to the A4R (11 x 8.5R) width
position, and press the
[EXECUTE] key.
60
60
-01
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of ICU PWB image
DRAM read/write.
Section
ICU (Memory)
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key, and memory read/write
operation check is started.
After completion of check, the result is displayed
with NG or OK.
61
61
-04
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (writing) unit (LED array
unit) skew.
Section
Scanner (writing)
Item
Operation
Operation/
Procedure
1. Set the print conditions of the scanner (writing)
unit (LED array unit) skew adjustment pattern.
2. Press the [EXECUTE] key.
The scanner (writing) unit (LED array unit) skew
adjustment pattern is printed.
Display
Content
Min.
Value
Max.
Value
Default
A PATTERN Print pattern specification
1: SKEW--- Used to
check scan tilt.
2: FOCUS --- Used to
check/adjust focus.
1
2
1
B LINE
PITCH
Dot print width (N-1)
specification
1
10
7
Display
Content
Note
C POSITION Pattern output area
selection
1
12
6
D MULTI
COUNT
Print quantity
1
999
1
E PAPER
Paper feed tray selection
(MFT, CS1,CS2, CS3,
CS4, LCC)
1
6
2
(CS1)
F EXIT
TRAY
Paper exit tray selection
(R, S)
1
2
1 (R)
63
63
-01
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to check the result of shading correction. (The
shading correction data are displayed.)
Section
Scanner (Exposure)
Item
Operation
Operation/
Procedure
Used to display the latest shading correction result.
Data for each color can be separately checked with
the color keys.
63
-03
Purpose
Adjustment
Function
(Purpose)
Used to adjust the CCD color balance (gamma).
Section
Scanner (Image scanning)
Item
Picture quality
Color balance
Operation/
Procedure
Set the SIT chart (UKOG-0280FCZZ) on the
document table, and press the [EXECUTE] key.
The color coefficient automatic adjustment pattern
reading is started to calculate and display the color
coefficient data.
The color coefficient data of each color can be
displayed with the color key.
Display
Content
Min.
Value
Max.
Value
Default
Summary of Contents for AR-BC320
Page 340: ...Memo ...