AR-BC320 SIMULATION 9 - 64
*1: Error code and its content
00: No error
01: Belt element defect
02: Insufficient Black patch density
03: Insufficient Cyan patch density
04: Insufficient Magenta patch density
05: Insufficient Yellow patch density
06: Main scanning direction fine adjustment Cyan patch print error
07: Main scanning direction fine adjustment Magenta patch print
error
08: Main scanning direction fine adjustment Yellow patch print
error
09: Sub scanning direction fine adjustment Cyan patch print error
10: Sub scanning direction fine adjustment Magenta patch print
error
11: Sub scanning direction fine adjustment Yellow patch print
error
12: Main scanning direction rough adjustment 1 Cyan patch print
error
13: Main scanning direction rough adjustment 1 Magenta patch
print error
14: Main scanning direction rough adjustment 1 Yellow patch print
error
15: Sub scanning direction rough adjustment 1 Cyan patch print
error
16: Sub scanning direction rough adjustment 1 Magenta patch
print error
17: Sub scanning direction rough adjustment 1 Yellow patch print
error
18: Main scanning direction rough adjustment 2 Cyan patch print
error
19: Main scanning direction rough adjustment 2 Magenta patch
print error
20: Main scanning direction rough adjustment 2 Yellow patch print
error
21: Sub scanning direction rough adjustment 2 Cyan patch print
error
22: Sub scanning direction rough adjustment 2 Magenta patch
print error
23: Sub scanning direction rough adjustment 2 Yellow patch print
error
98: Regist sensor error
99: Other error
When the adjustment value is changed, the image losses at the
four corners are changed uniformly.
2. The self print chart is printed, and the machine is brought into
the self print chart scan standby mode.
3. Select [SCAN], and the outputted self print chart is scanned.
4. Select [FINISH] to display the result display menu.
[DATA]: The scanned data are displayed.
DENSITY
CHECK M
Toner patch density value (M)
0
9999
DENSITY
CHECK Y
Toner patch density value (Y)
0
9999
REGIST
COUNT
Registration count (Transfer belt
mileage: A4 size is counted as 1.)
0
9999
EXECUTE
COUNT
Number of execution (Number of
execution /Number of execution
condition)
0
9999
Display
Content
Min.
Value
Max.
Value
50
-27
Purpose
Adjustment
Function
(Purpose)
Used to adjust image loss in the FAX/scanner
mode.
Section
FAX/Scanner
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment mode with the scroll key.
2. Enter the adjustment value at the selected point,
and press the [OK] key. The entered value is
set.
Display
Content
Min.
Value
Max.
Value
Default
A
FAX MODE image loss
0
99
20
B
PUSH SCAN MODE image
loss
0
99
30
C
PULL SCAN MODE image
loss
0
99
0
50
-28
Purpose
Adjustment
Function
(Purpose)
Used to adjust automatic void (service installation
adjustment).
Item
Picture quality
Image position
Operation/
Procedure
1. [ALL OPTION CS]: Select "For service
installation adjustment."
[CS ADJ]: Individual adjustment of cassette
[OC ADJ]: OC adjustment
[ADF ADJ]: ADF adjustment
[PRINT]: When [AUTO] is selected, the self print for
adjustment of CS1 and that for adjustment of MFT
are printed. (When [ADF] is selected, the output is
made from the currently set cassette.)