AR-BC320 SIMULATION 9 - 48
(Display items)
3. With the front cover of the machine open (cover open/close
switch OFF), turn on the power.
4. Enter the SIM44-13 mode.
5. Close the front cover of the machine.
6. Press the [EXECUTE] key.
Adjustment is performed automatically. After completion of
adjustment, the result is displayed and the [EXECUTE] key
display returns to the original state.
7. Remove the color image density sensor adjustment jig.
(Set items)
If the adjustment is not completed normally, "ERROR" is displayed.
In case of an error, the contents of the adjustment are not revised.
(Display items)
When the value exceeds the detection range, "-" is displayed.
∗
In case of an error in the above operation, "ERROR" is
displayed and the color balance adjustment data (half-tone
initial data) are not stored.
Display
Content
CARB DATA
Color image density sensor output level when
the calibration plate is detected by the basis of
the color image density sensor LED current
adjustment value.
ID (YMC)
Actual target density level in high density image
correction
ID (K)
Actual target density level in high density image
correction
n-1
Toner patch density (previous patch of nth patch
data) in high density image correction (Center
voltage - 50v) (n = 1 to 10))
n-2
Toner patch density (Medium patch of nth patch
data) in high density image correction (Center
voltage) (n = 1 to 10))
n-3
Toner patch density (following patch of nth patch
data) in high density image correction (Center
v 50v) (n = 1 to 10))
44
-13
Purpose
Adjustment
Function
(Purpose)
Color image density sensor adjustment (Adjustment
by the adjustment jig)
Section
Process (Transfer)
Operation/
Procedure
1. Open the front cover of the machine.
2. Install the color image density sensor
adjustment jig to the transfer unit frame, and
close the left cabinet.
Display
Content
Min
Value
Max
Value
Default
value
A
PCS_C
CARB ADJ
Color image density
sensor LED current
adjustment target value
1
255
108
B
PCS_C
DARK
Color image density
sensor dark voltage
level
0
255
0
C
PCS_C
LED ADJ
Color image density
sensor current
adjustment value
1
255
51
44
-14
Purpose
Adjustment/Setting/Operation data output, check
(display, print)
Function
(Purpose)
Used to monitor the output level of the fusing
temperature sensor, the machine temperature
sensor, and the humidity sensor.
Section
Others
Operation/
Procedure
The fusing temperature, the fusing thermistor
temperature, and the machine temperature and
humidity are displayed.
Display
Content
FUSER TEMPERATURE
CHECK HL1
Fusing temperature display Upper
(Temperature/AD value)
FUSER TEMPERATURE
CHECK HL2
Fusing temperature display Lower
(Temperature/AD value)
PROCESS
TEMPERATURE
Image process correction
temperature sensor temperature
display (Temperature/AD value)
PROCESS HUMIDITY
Image process correction humidity
sensor humidity display (Relative
humidity/AD value)
Developing temperature:
-20.0 to 40.0
Humidity:
0.0 to 99.9
Board temperature:
-20.0 to 80.0
44
-21
Purpose
Setting
Function
(Purpose)
Used to store color balance adjustment data. (Half
tone image correction initial setting) (After execution
of color balance adjustment with SIM 46-21, this
simulation must be executed.)
Section
Picture quality
Operation/
Procedure
1. Press the [EXECUTE] key, and it is highlighted
and the operation of color balance adjustment
data (half-tone correction initial data) storing is
started.
After completion of the execution, the
[EXECUTE] key returns to the normal display
Summary of Contents for AR-BC320