AR-BC320 DESCRIPTIONS OF EACH SECTION 7 - 62
[Main parts and others]
a. Original platform section
a-1. Original platform unit disassembly
1) Remove the screw, and remove (A) the rear subcover.
2) Detach the connector.
3) Remove the screws, and remove (B) the document feed tray.
4) Detach the connector.
5) Remove the screws, and take out the original width volume
unit.
6) Remove the screws, and detach (A) the original width volume.
a-2. Original length sensor disassembly
1) Remove the document feed tray.
2) Detach the connector.
3) Remove (A) original length sensor 1 and (B) original length
sensor 2.
b. Document feed section
b-1. Empty sensor disassembly
1) Open (A) the document feed cover.
2) Remove the screws.
3) Remove (B) the transport guide.
4) Detach the connector.
5) Remove (C) the empty sensor.
b-2. Front open sensor disassembly
1) Remove the screws.
2) Detach the connector, and remove (A) the front cover.
B
A
A
A
B
A
B
C
A
Summary of Contents for AR-BC320