AR-BC320 PRINTER CONTROLLER SECTION 14 - 11
NOTES:
• Correct adjustment will not be possible if you use the test patch
that is printed for "Auto color calibration" for the copy function or
any other document. If you attempt to use the wrong test patch,
you will return to the message screen that asks you to begin
automatic adjustment. Be sure to place only the test patch
printed out above on the document glass.
• Lay approximately five sheets of copy paper that are the same
size as the test patch on top of the set test patch, and gently
close the original cover.
When a message appears informing you that auto color calibration
is completed, touch the [OK] key to end the procedure.
NOTE: Before using this program, make sure that the registration
is correctly adjusted. If the registration is not correctly
adjusted, perform [AUTO ADJUSTMENT] in "Registration
adjustment".
e. Initialize and/or store settings
You can restore the CONDITION SETTINGS and the key operator
program of the PRINTER SETTINGS to the factory default set-
tings.
You can also store the current configuration of these settings in
memory, and restore a stored configuration at a later time.
1) Restore factory defaults
This restores the CONDITION SETTINGS and the key operator
program of the PRINTER SETTINGS to the factory default set-
tings.
If you need a record of the settings prior to restoration of the
default settings, print the CUSTOM SETTINGS list and the key
operator program list.
This does not affect "Color adjustments" in the PRINTER SET-
TINGS.
NOTE: After this program is set, exit the key operator program,
turn off the main switch, and then turn on the main switch
again after at least 3 seconds. The program will be effec-
tive at this time.
2) Store current configuration
This program is used to store the CONDITION SETTINGS and the
key operator program PRINTER SETTINGS in memory. The
stored settings will remain in memory even if the main switch is
turned off. To read the stored settings, use the following
[RESTORE CONFIGURATION] program.
This does not affect "Color adjustments" in the PRINTER SET-
TINGS.
3) Restore configuration
This program is used to read the configuration that was stored
using the [STORE CURRENT CONFIGURATION] program and
restore it as the current configuration.
The currently set configuration will change to the configuration
read from memory.
B. Jumper Setting
Configuration for 3-pin jumper is shown as follows.
(1) Boot ROM Write Protect setting (JP1)
(2) Battery setting (JP7)
6. Operation
A. Printer driver setting and operation
(1) Document mode and image process
Boot ROM Write Protect
JP1
Factory Default
Normal
1-2 Short
Write Protect
2-3 Short
←
Battery
JP7
Factory Default
ON
1-2 Short
←
OFF
2-3 Short
JP1
VCCWB
BOOT
3
1
L
⇔
H
JP7
BATTERY
1
OFF
⇔
ON
3
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...