AR-BC320 SIMULATION 9 - 66
2. Enter the set value with the 10-key and press the [OK] key to
set the entered value.
3. Press the [EXECUTE] key.
∗
If there is no paper on the duplex tray, one sheet of the
selected paper is fed and transported to the duplex tray.
Then the entered value in procedure 3 is set and the
alignment plate moves according to the home position
corresponding to the entered value.
∗
The paper sizes which can be used for transport and
alignment plate adjustment with SIM52-01 are LT, LTR, A4,
A4R, B5, B5R, 16K, and 16KR only. (For the other sizes,
"FEED ENABLE" occurs.)
(Set items)
• When the set value is changed by 1, it is changed by about
0.2mm. When the set value is increased, the alignment plate
paper width is narrowed. The adjustment value can be adjusted
in the increment of ±50 with 50 as the center value.
(Items to be set)
2. Press the [EXECUTE] key. The adjustment of the sensor
selected in procedure 1 is started. During execution of the
adjustment, the [EXECUTE] key is highlighted. If the
[EXECUTE] key is pressed under this state, the adjustment
can be interrupted.
∗
After completion of the adjustment, the COMPLETE display is
shown. In case of an abnormality, the INCOMPLETE display is
shown.
(Set items (sensors))
52
52
-01
Purpose
Adjustment
Function
(Purpose)
Used to adjust the duplex print mode stacking
capacity (Used to adjust the stop position of the
duplex unit paper tray width alignment plate. The
home position of the width alignment plate is
changed by software.)
Section
Duplex
Item
Operation
Operation/
Procedure
1. Select the adjustment mode with the scroll key.
∗
When the machine is not ready for paper feed,
"NOT READY" is displayed. When the
corresponding tray is unable to feed, "FEED
UNABLE" is displayed. If it is able to feed,
"FEED ABLE" is displayed.
Item
Set
range
Default
A
Intermediate tray alignment plate
adjustment value (Manual feed)
0 – 99
50
B
Intermediate tray alignment plate
adjustment value (Cassette 1)
0 – 99
50
C
Intermediate tray alignment plate
adjustment value (Cassette 3)
0 – 99
50
D
Intermediate tray alignment plate
adjustment value (Cassette 4)
0 – 99
50
E
Intermediate tray alignment plate
adjustment value (LCC)
0 – 99
50
53
53
-01
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document stop position in each
operation mode of the RADF.
Section
RADF
Item
Operation
Operation/
Procedure
1. Select the adjustment mode with the scroll key.
2. Enter the set value with the 10-key and press
the [OK] key to set the entered value.
This simulation is used to adjust the stop timing of
the document transport belt.
Item
Set
range
Default
A
NORMAL (S)
Document stop position
adjustment with normal
paper in single copy
1 – 15
8
B
NORMAL (D)
Document stop position
adjustment with normal
paper in duplex copy
1 – 15
8
53
-02
Purpose
Adjustment
Function
(Purpose)
Used to adjust the optical sensor sensitivity in
RADF.
Section
RADF
Item
Operation
Operation/
Procedure
1. The sensor names are displayed. Select the
sensor to be adjusted with the key.
Display
Content
Note
RESIST
Resist sensor
REVERSE
Reverse sensor
TIMING
Timing sensor
TRAYVOLA4R
Tray A4R
(11 x 8.5R)
width sensor
After selecting
TRAYVOLA4R, set the tray
document guide to A4R (11 x
8.5R) position, and press the
[EXECUTE] key.
TRAYVOLMIN
Tray paper min.
width detection
After selecting
TARYVOLMIN, set the tray
document guide to the
minimum width position, and
press the [EXECUTE] key.
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...