AR-BC320 SIMULATION 9 - 81
3. Set the color patch image (adjustment pattern) printed in SIM
67-25 on the document table, and press [EXECUTE] key.
[EXECUTE] key is highlighted and sampling is executed.
4. After completion of the operation, [EXECUTE] key is returned
to the normal display, and the sampling result is displayed.
When [REPEAT] key is pressed, the process returns to
procedure 3).
5. Press the [OK] key.
The displayed target value is saved to the backup area as the
target value.
∗
For BASE, only the sampling result display menu is displayed.
1. Press the [EXECUTE] key.
2. Select [YES]. (If [NO] is selected, the display returns to the
initial display.)
The value is reset to the standard value, and the data are saved to
the backup area.
Printer screen selection. When DEF is 0, it is the same as the
conventional screen. When DEF is 1, it is an option screen with
improved grainy. (However, the number of lines of the screen is
reduced.)
2. Insert the copy source ROM into the font ROM socket.
3. Press the [EXECUTE] key.
4. ROM data initializing, writing, and verifying are performed.
∗
When the result is displayed, CA key and the CUSTOM
SETTINGS key become valid.
67
-27
Purpose
Adjustment
Function
(Purpose)
Used to display and register the scanner target
value (for servicing) of the printer engine automatic
density adjustment. (Conforms to the service button
of SIM 67-24. (The serviceman can scan the target
value.))
Operation/
Procedure
1. Select a color for sampling.
2. Press [SETUP] key.
Display data
Display content
B
Target value of point B
C
Target value of point C
D
Target value of point D
E
Target value of point E
F
Target value of point F
G
Target value of point G
H
Target value of point H
I
Target value of point I
J
Target value of point J
K
Target value of point K
L
Target value of point L
M
Target value of point M
N
Target value of point N
O
Target value of point O
BASE
Base sampling value
67
-28
Purpose
Adjustment
Function
(Purpose)
Used to reset the scanner target value (for servicing)
in the printer engine automatic density adjustment to
the standard value. (Reset to the standard value of
SIM67-27. (The value is reset to the factory setting.))
Operation/
Procedure
The registration target value set with SIM67-27
(Printer engine automatic density adjustment
scanner target value (for servicing) display &
registration) is reset to the standard value.
67
-29
Purpose
Setting
Function
(Purpose)
Used to set the printer screen mode.
Operation/
Procedure
1. Select a set item with the scroll key.
2. Enter a set value with the 10-key.
3. Press the [OK] key.
Item
Content
Set
range
Default
A
4BIT PHOTO AREA
0:PHOTO1 1:PHOTO2
0 – 1
1
B
4BIT GRAPHICS AREA 0:GRAPHICS1
1:GRAPHICS2
0 – 1
0
C
4BIT CAD SCREEN
0:CAD1 1:CAD2
0 – 1
1
67
-40
Purpose
Setting
Function
(Purpose)
Used to copy the scanner destination. (Flash writing)
Section
Flash ROM (Scanner)
Item
Data
Writing
Operation/
Procedure
1. Insert a new ROM of copy destination into the
socket of the firm ROM.
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...