AR-BC320 TROUBLESHOOTING 11 - 7
Main
code
Sub
code
Title
Finisher transport motor trouble
(Finisher detection)
F1
02
Display
Lamp/Message
Phenomenon Detail
Transport motor drive
trouble
Section
Transport
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
transport motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Main
code
Sub
code
Title
Finisher paddle motor trouble
F1
03
Display
Lamp/Message
Phenomenon Detail
Paddle motor operation
trouble
Section
Finisher
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Main
code
Sub
code
Title
Finisher slide motor trouble
F1
06
Display
Lamp/Message
Phenomenon Detail
Slide motor operation
trouble
Section
Finisher
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Main
code
Sub
code
Title
Finisher staple motor trouble
(Finisher detection)
F1
10
Display
Lamp/Message
Phenomenon Detail
Stapling operation trouble
Section
Finisher
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
staple motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Main
code
Sub
code
Title
Finisher bundle process motor
trouble (Finisher detection)
F1
11
Display
Lamp/Message
Phenomenon Detail
Bundle process motor
trouble
Section
Finisher
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
staple motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Main
code
Sub
code
Title
Finisher tray lift motor trouble
(Finisher detection)
F1
15
Display
Lamp/Message
Phenomenon Detail
Lift motor trouble
Section
Finisher
Case 1
Cause
Motor lock
Check &
Remedy
Use SIM 3-3 to check the
staple motor operation.
Case 2
Cause
Motor RPM abnormality
Check &
Remedy
Same as Case 1.
Case 3
Cause
Over current to the motor
Check &
Remedy
Same as Case 1.
Case 4
Cause
Console finisher control
PWB trouble
Check &
Remedy
Same as Case 1.
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...