AR-BC320 TROUBLESHOOTING 11 - 24
Main
code
Sub
code
Title
EEPROM read/write error (SCN)
U2
80
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
Section
—
Case 1
Cause
EEPROM trouble,
Insertion of EEPROM
which is not initialized or
defective.
Check &
Remedy
1. Check that the
EEPROM is properly
inserted.
2. Use SIM 16 to cancel
the error.
Case 2
Cause
SCN PWB EEPROM
access circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is
installed, use SIM 22-1
to record the counter
data and the adjustment
data.)
2. Replace the SCN PWB.
3. Use SIM 16 to cancel
the error.
Main
code
Sub
code
Title
Adjustment value check sum error
(SCN)
U2
81
Display
Lamp/Message
Phenomenon Detail
EEPROM (SCN) check
sum error
Section
—
Case 1
Cause
EEPROM trouble
Check &
Remedy
1. Check that the
EEPROM is properly
inserted.
2. Use SIM 16 to cancel
the error.
Case 2
Cause
SCN PWB EEPROM
access circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is
installed, use SIM 22-1
to record the counter
data and the adjustment
data.)
2. Replace the SCN PWB.
3. Use SIM 16 to cancel
the error.
Main
code
Sub
code
Title
EEPROM read/write error (PCU)
U2
90
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
Section
—
Case 1
Cause
EEPROM trouble,
Insertion of EEPROM
which is not initialized or
defective.
Check &
Remedy
1. Check that the
EEPROM is properly
inserted.
2. Use SIM 16 to cancel
the error.
Case 2
Cause
PCU PWB EEPROM
access circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is
installed, use SIM 22-1
to record the counter
data and the adjustment
data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel
the error.
Main
code
Sub
code
Title
Adjustment value check sum error
(PCU)
U2
91
Display
Lamp/Message
Phenomenon Detail
EEPROM (PCU) check
sum error
Section
—
Case 1
Cause
EEPROM trouble
Check &
Remedy
1. Check that the
EEPROM is properly
inserted.
2. Use SIM 16 to cancel
the error.
Case 2
Cause
Control circuit freeze
caused by noises, PCU
PWB EEPROM access
circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is
installed, use SIM 22-1
to record the counter
data and the adjustment
data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel
the error.
Summary of Contents for AR-BC320
Page 340: ...Memo ...
Page 341: ...Memo ...