AR-BC320 TROUBLESHOOTING 11 - 20
H4
00
Case 2
Cause
The heater lamp keeps ON
with SIM 5-2. Heater lamp
trouble, thermostat trouble,
interlock switch trouble, AC
power supply trouble, PCU
PWB (lamp control circuit)
trouble
Check &
Remedy
Check for disconnection of
the heater lamp and the
thermostat. Check the
interlock switch. Check the
AC PWB and the PUC
PWB lamp control circuit.
Cancel the error with SIM
14.
Main
code
Sub
code
Title
Fusing section low temperature
trouble (HL2)
H4
01
Display
Lamp/Message
Phenomenon Detail
The fusing temperature is
not reached within the
specified time after turning
on the power relay.
Section
Fusing
Common
Check
Use SIM 5-2 to check the
heater lamp flashing
operation.
Case 1
Cause
The heater lamp flashes
properly with SIM 5-2.
Thermistor trouble, PCU
PWB (thermistor input
circuit) trouble
Check &
Remedy
Check the thermistor and
its harness. Check the
PCU PWB thermistor input
circuit.
Cancel the error with SIM
14.
Case 2
Cause
The heater lamp keeps ON
with SIM 5-2.
Heater lamp trouble,
thermostat trouble,
interlock switch trouble, AC
power supply trouble, PCU
PWB (lamp control circuit)
trouble
Check &
Remedy
Check for disconnection of
the heater lamp and the
thermostat. Check the
interlock switch. Check the
AC PWB and the PUC
PWB lamp control circuit.
Cancel the error with SIM
14.
Main
code
Sub
code
Title
Fusing section low temperature
trouble (HL1)
Main
code
Sub
code
Title
Five continuous detections of
POD1 not-reached jam
H5
01
Display
Lamp/Message
Phenomenon Detail
POD1 not-reached jams
are detected for five times
continuously.
Section
Fusing
Case 1
Cause
A fusing jam is not
canceled completely. (Jam
paper remains inside the
machine.)
Check &
Remedy
Check remaining jam
paper (winding).
Cancel the error with SIM
14.
Case 2
Cause
POD1 sensor trouble, or
harness disconnection
Check &
Remedy
Check POD1 sensor
harness.
Cancel the error with SIM
14.
Case 3
Cause
Improper installation of the
fusing unit
Check &
Remedy
Check installation of the
fusing unit.
Cancel the error with SIM
14.
Main
code
Sub
code
Title
Mirror feed trouble
L1
00
Display
Lamp/Message
Phenomenon Detail
Mirror feed is not
completed within the
specified time.
Section
—
Case 1
Cause
Mirror unit trouble, mirror
wire breakage
Check &
Remedy
Use SIM 1-1 to check the
mirror operation.
Main
code
Sub
code
Title
Mirror return trouble
L3
00
Display
Lamp/Message
Phenomenon Detail
Mirror return is not
completed within the
specified time.
Section
—
Case 1
Cause
Mirror unit trouble, mirror
wire breakage
Check &
Remedy
Use SIM 1-1 to check the
mirror operation.
Summary of Contents for AR-BC320