AR-BC320 TROUBLESHOOTING 11 - 12
Main
code
Sub
code
Title
Toner empty sensor abnormality
(Magenta)
F2
42
Display
Lamp/Message
Phenomenon Detail
Toner empty sensor output
abnormality
Section
Cartridge
Case 1
Cause
Connector harness
trouble, connector
disconnection
Check &
Remedy
1. Check connection of the
toner empty sensor.
→
Connect it properly.
2. Check connection of the
connector harness to
the PCU PWB.
→
Connect it properly.
3. Check connection of the
cartridge.
→
Connect it
properly.
4. Check for disconnection
of the harness.
→
Replace the harness.
Case 2
Cause
Cartridge trouble
Check &
Remedy
Replace the cartridge.
Main
code
Sub
code
Title
Toner empty sensor abnormality
(Yellow)
F2
43
Display
Lamp/Message
Phenomenon Detail
Toner empty sensor output
abnormality
Section
Cartridge
Case 1
Cause
Connector harness
trouble, connector
disconnection
Check &
Remedy
1. Check connection of the
toner empty sensor.
→
Connect it properly.
2. Check connection of the
connector harness to
the PCU PWB.
→
Connect it properly.
3. Check connection of the
cartridge.
→
Connect it
properly.
4. Check for disconnection
of the harness.
→
Replace the harness.
Case 2
Cause
Cartridge trouble
Check &
Remedy
Replace the cartridge.
Main
code
Sub
code
Title
Black image density sensor
trouble (Transfer belt surface
reflection ratio abnormality)
F2
44
Display
Lamp/Message
Phenomenon Detail
Before starting process
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However,
when the sensor gain is
changed, the output is not
within the specified range.
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1
Cause
When "Error" occurs in
SIM 44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
3. Calibration plate
solenoid operation
trouble
Check &
Remedy
1. Clean/replace the
image density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
3. Replace the calibration
plate solenoid.
Case 2
Cause
When SIM 44-2 is
completed:
1. Insufficient cleaning of
the transfer belt.
Check &
Remedy
1. Check the transfer belt
surface.
Main
code
Sub
code
Title
Color image density sensor
trouble (Calibration plate surface
reflection ratio abnormality)
F2
45
Display
Lamp/Message
Phenomenon Detail
Before starting process
control, the calibration
plate surface is scanned
with the image density
sensor to adjust the sensor
gain so that the output
becomes a fixed value.
However, when the sensor
gain is changed, the output
is not within the specified
range.
Section
—
Common
Check
Use SIM 44-2 to adjust the
process control sensor
gain.