8.6 Service parts
8-44
8
Maintenance
8.6 Service parts
8.6.1 The parts requiring Inspection
Some parts have aging degradation.
Please request us an overhaul by referring to the periods below for preventive maintenance.
■
Capacitor for smoothing the main circuit, and relays
Inspection is needed if the servo amplifier has stored for more than 3 years. Contact the
dealer or sales office.
It is necessary to replace the capacitor that is earlier than 5 years when it is used to
exceed yearly average 40°C or exceed more than 50% of the rated output current of
servo amplifier.
It is necessary to replace the capacitor or relays that are earlier than periods above
where the main power-cycle is repeated more than 30 times per day or 5 times per hour.
Capacity reduction or early failure of relays is considered.
No.
Part name
Number of average
replacement
periods
Corrective measures / usage conditions
1
Aluminum electrolytic capacitor
for smoothing main circuit
5 Years
Replacement with new part is necessary.
Load ratio: 50% of rated output current of
amplifier.
Usage condition: Yearly average 40°C
2 Cooling
Fan
motor
5
Years
Replacement with new part is necessary.
Usage condition: Yearly average 40°C
3
Lithium battery for absolute
encoder [ER3VLY]
3 Years
Replacement with new part is necessary.
4
Aluminum electrolytic capacitor
(other than capacitor for
smoothing main circuit)
5 Years
Replacement with new part is necessary.
Usage condition: Yearly average 40°C
Annual total usage time is 4800 hours.
5
Fuse
10 Years
Replacement with new part is necessary.
6 Relays
(Power-cycle: a
hundred thousand
times)
Replacement with new part is necessary.
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...