5. Operation
5-103
Group9 List of selection contents
■
Keeping the function always valid or invalid
■
Using function with the generic input signals
■
Activating the functions conditioning the rotational speed of servomotor
Selection
Contents
00
Always_Disable Function is always invalid
01
Always_Enable
Function is always valid
Selection
Contents
02
CONT1_ON
Function is valid when generic input, CONT1, is ON
03
CONT1_OFF
Function is valid when generic input, CONT1, is OFF
04
CONT2_ON
Function is valid when generic input, CONT2, is ON
05
CONT2_OFF
Function is valid when generic input, CONT2, is OFF
06
CONT3_ON
Function is valid when generic input, CONT3, is ON
07
CONT3_OFF
Function is valid when generic input, CONT3, is OFF
08
CONT4_ON
Function is valid when generic input, CONT4, is ON
09
CONT4_OFF
Function is valid when generic input, CONT4, is OFF
0A
CONT5_ON
Function is valid when generic input, CONT5, is ON
0B
CONT5_OFF
Function is valid when generic input, CONT5, is OFF
0C
CONT6_ON
Function is valid when generic input, CONT6, is ON
0D
CONT6_OFF
Function is valid when generic input, CONT6, is OFF
0E
CONT7_ON
Function is valid when generic input, CONT7, is ON
0F
CONT7_OFF
Function is valid when generic input, CONT7, is OFF
10
CONT8_ON
Function is valid when generic input, CONT8, is ON
11
CONT8_OFF
Function is valid when generic input, CONT8, is OFF
Selection
Contents
12
LOWV_IN
Function is valid while in low speed status
(speed is lower than the LOWV Setting Value).
13
LOWV_OUT
Function is valid while not in low speed status
(speed is lower than the LOWV Setting Value).
14
VA_IN
Function is valid while in speed attainment status
(speed is higher than the VA Setting Value).
15
VA_OUT
Function is valid while not in speed attainment status
(speed is higher than the VA Setting Value).
16
VCMP_IN
Function is valid while in speed matching status
(within command-actual velocity consistent range).
17
VCMP_OUT
Function is valid while not in speed matching status
(within command-actual velocity consistent range).
18
ZV_IN
Function is valid while in zero speed status
(speed is lower than the ZV Setting Value).
19
ZV_OUT
Function is valid while not in zero speed status
(speed is lower than the ZV Setting Value).
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...