5. Operation
5-127
-
GroupC
-
ID
Contents
04
Encoder Output Pulse Division
[ENRAT]
Setting range
Unit
Default value
1/1 to 1/64
2/3 to 2/64
1/32768 to 32767/32768
-
1/1
■
Sets ratio of Encoder output pulse division.
When the numerator of the dividing ratio is 1, setting range of the denominator is 1 (not
divide), 2-64 or 32768.
When the numerator of the dividing ratio is 2, setting range of the denominator is 3-64 or
32768.
When the denominator of the dividing ratio is 32768, setting range of the numerator is
1-32767.
Z phase output is not divided.
After Control power ON, for 2s at maximum, the ratio is unstable.
05
Encoder Output Pulse Divide Polarity
[PULOUTPOL]
Setting range
Unit
Default value
00 to 03
-
00:Type1
■
Sets division polarity of Encoder output pulse.
Selection
Contents
00
Type1
A Phase Signal/Not Reversed
Z Phase Signal Logic/High Active
01
Type2
A Phase Signal/Reversed
Z Phase Signal Logic/High Active
02
Type3
A Phase Signal/Not Reversed
Z Phase Signal Logic/Low Active
03
Type4
A Phase Signal/Reversed
Z Phase Signal Logic/Low Active
Dividing ratio 1/1
(forward rotation)
Phase A
Phase B
Phase Z
90°
Dividing ratio 1/2
(forward rotation)
90°
Phase A
Phase B
Phase Z
Dividing ratio 2/5
(forward rotation)
108° (90° is not possible phase relation does not change)
Phase
A
Phase
B
Phase
Z
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...