8. Maintenance
8-17
■
Alarm Code 54 (Built-in Regenerative Resistance Overheat)
Corrective
actions
* When using a regenerative resistor built in the servo amplifier, make sure to set “01:
Built-in_R“ at the system parameter ID03 “Regenerative Resistor Selection”. This setting decides
enabled/disabled of the overheating protection detection treatment of the built-in regeneration
resistance.
* Built-in regenerative resistance overheat does not detected when “02 External_R“ is selected.
Therefore, there is a danger that built-in regenerative resistance will burn out or be damaged.
Status at the time of alarm
Cause
1
2
3
Issued when control power supply is turned
ON.
✔
✔
Issued during operation.
✔
✔
✔
Cause
Investigation and corrective actions
1
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
2
■
Regenerative power excessive.
■
Check the built-in regenerative
resistor allowable power.
■
Check the operating conditions to
keep that consumption power is
below of allowable power.
■
Use an external regenerative
resistor.
3
■
Resistor wiring is wrong at built-in
regenerative resistor model.
■
Check the wiring conditions and
correct it if improper.
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...