8. Maintenance
8-15
■
Alarm code 43 (Regenerative Overload)
Corrective
actions
* If the setting of system parameter ID03 “Regenerative Resistor Selection” is incorrect,
regeneration overload is not detected properly, and the amplifier and surrounding circuit may be
damaged or burnt.
■
Alarm code 45 (Average continuous over speed)
Corrective
actions
Status at the time of alarm
Cause
1
2
3
4
5
6
7
8
Issued when control power supply is turned ON.
✔
Issued when main circuit power supply is turned ON.
✔
✔
✔
✔
✔
✔
Issued during operation.
✔
✔
✔
✔
Cause
Investigation and corrective actions
1
■
Exceeds a permitted value of the
regenerative power at built-in
regenerative resistance model.
■
Excessive load inertia moment, or
tact time is short.
■
Check the load and operating
conditions.
■
Change to external regenerative
resistor.
■
Set to be the load inertia moment
within the specified range.
■
Increase the deceleration time.
■
Increase the tact time.
2
■
Regenerative resistor is connected
to the model without regenerative
resistor.
■
Remove regenerative resistor.
3
■
Resistor wiring is wrong at built-in
or external regenerative resistor
model.
■
Check the wiring conditions and
correct it if improper.
4
■
Regenerative resistor wire breaks.
■
For built-in regeneration resistor
specifications, replace the servo
amplifier.
■
For external regeneration resistor
specifications, replace the
regeneration resistor.
5
■
Resistance value of external
regenerative resistor is excessive.
■
Replace to the resister that
matching the specifications.
6
■
Input power supply voltage
exceeds the specified range.
■
Check the input power supply
voltage level.
7
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
8
■
External regenerative resistor does
not connect although "02:
External_R" is set in the system
parameter ID03 "Regenerative
resistor selection".
■
Connect external regenerative
resistor.
■
Set "00: Not_connect" in the
system parameter ID03
"Regenerative resistor selection".
Status at the time of alarm
Cause
1
Occurred during operation.
✔
Cause
Investigation and corrective actions
1
■
The average speed exceeds the
maximum speed of continuous
rotation speed range.
■
Review the operating conditions.
■
Resize the servo motor.
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...