8.3 Trouble shooting when alarm activated
8-16
8
Maintenance
■
Alarm Code 52 (In-rush prevention resistance Overheat)
Corrective
actions
■
Alarm Code 53 (Dynamic Brake Resistor Overheat)
Corrective
actions
Cause
Investigation and corrective actions
1
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
2
■
Power turning ON is repeated too
frequently.
■
Turn ON/OFF the power less
frequently.
3
■
Ambient temperature is high.
■
Confirm temperature in cabinet (or
ambient of the amplifier), then
refine installation method of the
servo amplifier and ventilation of
the cabinet.
Status at the time of alarm
Cause
1
2
3
Issued when control power supply is turned
ON.
✔
Issued when main circuit power supply is
turned ON.
✔
Issued during operation.
✔
Status at the time of alarm
Cause
1
2
Issued when control power supply is turned
ON..
✔
Issued during operation.
✔
✔
Cause
Investigation and corrective actions
1
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
2
■
Dynamic Brake operation is
repeated too frequently.
■
Use the dynamic brake so as not to
exceed the permissive frequency.
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...