5.Operation
5-139
5.10.3 Notes
Set torque limit value under voltage sag warning smaller than that of normal operation.
Even if the torque limit value of voltage sag is greater than that of normal operation, it limits the
torque at the set value when in voltage sag. After power restoration, the limiting value goes back
to that of normal operation.
Control power
voltage
Bus voltage
Control power
drop Warning
detected
Torque
limit value
Instantaneous power interruption
Approx.150V
(AC200-specificaiton)
10ms
Torque limit value
selected by TLSEL
Torque limit value
selected by CPETLSEL