5.8 Parameter functions
5-122
5
O
per
ation
-
GroupB
-
ID
Contents
06
Power Failure Detection Delay Time
[PFDDLY] “Power cycle for control after setting”
Setting range
Unit
Default value
20 to 1000
ms
32
■
Sets the delay time from Control power OFF to Control power error detection.
The larger value makes the detection of Instantaneous stop slower.
(Control power holding time:
200V ac input type: about 100msec
100V ac input type: about 80msec
Larger set value will only result in slower detections of errors. In case of power failure of Internal
logic circuit, operation is same as when Control power is turned ON again. In case of energy
shortage of Main circuit power, other errors such as Main circuit power loss may be detected.)
In this setting, actual detection delay time varies by -12ms to +6ms.
07
Initial timeout wait time
[INTTIM] “Power cycle for control after setting”
Setting range
Unit
Default value
00 to 07
-
00:Disabled
■
Selects the time till initialization completion.
10
Excessive Deviation Warning Level
[OFWLV]
Setting range
Unit
Default value
1 to 2147483647
Pulse
2147483647
■
Sets Warning output level before Excessive position deviation alarm is output.
Sets at Encoder pulse resolution regardless of Electronic gear.
✔
It will be limited to 1073741823 [Pulse] if the value is set exceeding
1073741823[Pulse].
11
Deviation Counter Overflow Value
[OFLV]
Setting range
Unit
Default value
1 to 2147483647
Pulse
5000000
■
Sets Position deviation value regarded as Excessive position deviation alarm.
Sets at Encoder pulse resolution regardless of Electronic gear.
✔
It will be limited to 1073741823 [Pulse] if the value is set exceeding
1073741823[Pulse].
12
Overload Warning Level
[OLWLV] “Power cycle for control after setting”
Setting range
Unit
Default value
20 to 100
%
90
■
Sets the Warning output level before Overload alarm output.
The possible level to be set is from 20%-99%, assuming that the Overload Warning
Level is 100%. When set to 100%, Overload warning and Overload alarm are output at
one time.
Overload detection is assumed and set as 75%, of a rated load when Control power is
turned ON (hot start). Therefore, Overload warning may be output when Control power is
turned ON.
13
Velocity Feedback Alarm (ALM_C3) Detection
[VFBALM]
Setting range
Unit
Default value
00 to 01
-
01:Enabled
■
Selects Valid/Invalid Velocity feedback error detection.
Selection
Contents
00
Disabled
Invalid
01
Enabled
Valid
Selection
Contents
00
Disabled Without wait time
01
1000ms
Insert 1000ms wait
02
1400ms
Insert 1400ms wait
03
1800ms
Insert 1800ms wait
04
2000ms
Insert 2000ms wait
05
3000ms
Insert 3000ms wait
06
5000ms
Insert 5000ms wait
07
10000ms Insert 10000ms wait
Summary of Contents for Sanmotion R 3E S
Page 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Page 2: ......
Page 76: ...No Text on This Page ...
Page 88: ...No Text on This Page ...
Page 266: ...No Text on This Page ...
Page 332: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 444: ...No Text on This Page ...
Page 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Page 512: ...No Text on This Page ...