Lantronix
ION x6010 User Guide
33493 Rev. F
Page 63 of 261
Circuit ID
– either blank or the information entered earlier displays (read/write field).
Link Status
– either
Down
or
Up
displayed (read only field).
AIS Transmit
– Select
All Ones
or
Blue
on the Port 1 copper interface as an error signal when the
copper interface is down. When this error signal is transmitted, the AIS of the device on the
other end is activated, if supported (read/write field).
Transmit All Ones
– Transmit AIS (All Ones:1111... sequence / BLUE:0101... sequence) on the
Port 1 copper interface as an error signal for the DS3/E3/STS-1 port.
Alarm Indication Signal
– When “
Alarm
” displays, this means that the other end has TAOS
enabled and is currently transmitting an alarm condition. When “
Normal
” displays, this means
no alarm (read only field).
Long Haul
– This variable indicates the current position of the remote device’s Short/Long haul
configuration switch (read only field).
TDM Mode
– This variable indicates the type of the current device. T1=1.544MHz;
E1=2.048MHz; E3=34.4Mb/s; DS3 = 44.7Mbps; STS-1 = 51.8Mbps.
Line Build Out
– The characteristics of the x6010’s copper interface (read only field) as defined
by DIP switch. An x60xx with Coax interface works in E1 mode only; in this mode the Line Build
Out is e12-37V75ohms.
Connector Type
–
RJ45, SFP Dual BNC
, etc. – model dependent (read only field).
Loopback Type
– either “No Loopback” or “PHY layer” loopback displayed.
Loopback Status
– either “
Local In Loopback
” or “
No Loopback
” displayed.
17.
Verify the C6010
Port 2
(fiber port) configuration settings:
Circuit ID
– either blank or the information entered earlier displays.
Link Status
– either
Down
or
Up
displayed (read only field).
AIS Transmit
– Select
All One
s or
Blue
on the Port 2 fiber interface as an error signal when the
Port 2 fiber interface is down. When this error signal is transmitted, the AIS of the device on the
other end is activated, if supported (read/write field).
Transmit All Ones
– Transmit AIS (All Ones:1111... sequence / BLUE:0101... sequence) on the
Port 2 fiber interface as an error signal for the DS3/E3/STS-1 port (read only field).
Alarm Indication Signal
– When “
Alarm
” displays, this means that the other end has TAOS
enabled and is currently transmitting an alarm condition. When “
Normal
” displays, this means
no alarm (read only field).
Connector Type
–SFP Slot, etc. – model dependent (read only field).
Loopback Type
– either “
No Loopback
” or “
PHY layer
” loopback displayed (read/write field).
Loopback Status
– either “
Local In Loopback
” or “
No Loopback
” displayed.
Rx Power Intrusion Threshold
– from 0-
65535 μW. The default is 0 uW.
(DMI tab)