Command incomplete
This message indicates that not all of the required fields were entered for the CLI command.
1.
Verify the command syntax. Re-enter the command followed by a question mark (?) with a space
between the command and the question mark. The possible keywords that you can enter with the
command appear.
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
.
3.
If the problem persists, contact Technical Support.
Could not open connection to the host on port 23. Connection failed.
This message indicates that the Telnet server and client are configured for different ports. For Telnet
operations the default port is 23.
1.
Ensure that the Telnet port is set to 23 for both the server and the client. This will require someone
with administrative rights in order to make a change.
2.
Add the port number to the Telnet command. Example:
Telnet
<ipaddr> <port#>
3.
If the problem persists, contact Technical Support.
Error: this command should be executed on a device
This message indicates that the CLI command was entered for a port and it only applies to a device.
1.
Use the
go
command to change location of where the command operates. The format is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.
Error: this command should be executed on a port
This message indicates that the CLI command was entered for a card and it is only applicable for a port.
1.
Use the
go
command to change location of where the command operates. The
go
command format
is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.