Lantronix
ION x6010 User Guide
33493 Rev. F
Page 204 of 261
Parameter
Possible
Values
Description
Interface Characteristics
DMI ID
Unknown,
SFP/SFP+/SFP28,
GBIC, SFP,
Reserved, vendor-
specific
Specifies the physical device from SFF-8472 Rev 9.5 Standard:
00h Unknown or unspecified
01h GBIC
02h Module/connector soldered to motherboard
03h SFP
04-7Fh Reserved
80-FFh Vendor specific
Connector
Type
LC, MT-RJ LC, SC,
ST, RJ-45, or VF-
45, or unknown
The external optical or electrical cable connector provided as
the interface.
* MT-RJ: Media Termination – Recommended Jack for Duplex
multimode connections.
* LC: Lucent Connector or Local Connector for High-density
connections, SFP transceivers.
* SC: Subscriber Connector for Datacomm and Telecomm.
* ST: BFOC Straight Tip / Bayonet Fiber Optic Connector for
Multimode – rarely Singlemode (APC not possible).
* VF-45: Snap connector for Datacom uses.
See “
Connector Types
” section below.
Nominal Bit
Rate Mbps)
(measured rate)
Bitrate in units of 100Mbps (the sample screen above shows
1300, or 1.3 Gbps).
Fiber Interface
Wavelength
(nM)
(measured wave-
length)
The Nominal transmitter output wavelength at room tempera-
ture. The unit of measure is nanometers (the sample screen
above shows 850 nm).
Diagnostic Monitoring
Receive Power
(uW)
(measured power
measurement)
Receive power on local fiber measured in microwatts (the sam-
ple screen above shows
203
uW).
Receive Power
(dBM)
(measured signal
strength)
Receive power on local fiber measured in dBM (decibels rela-
tive to one milliwatt) which defines signal strength. The sample
screen above shows -
6.925
dBM.
Receive Power
Alarm
Normal -1,
Not Supported – 2,
Low Warn – 3,
High Warn – 4,
Low Alarm – 6
High Alarm – 7
Alarm status for receive power on local fiber.
Rx Power In-
trusion Thresh-
old (uW)
0 –
65535 μW
A configurable level for Rx Power on the Fiber port. If the DMI
read value falls below the preset value, an intrusion is detected,
and a trap is generated. The valid range is 0 –
65535 μW
. The
default is 0. Displays the message “
ALARM: Receive power is
below specified threshold. Fiber trap intrusion may be in pro-
gress.
” If the value falls below the specified threshold.
Temperature
(˚C)
(measured temp.)
Temperature of fiber transceiver in tenths of degrees C (Cel-
sius). The sample screen above shows 38.0
˚C.
Temperature
(˚F)
(measured temp.)
Temperature of fiber transceiver in tenths of degrees F (Fahren-
heit). The sample screen above shows 101.8
˚F.