Error, you should first give full location parameters
The location value is incomplete; it is missing the module, slot and/or port value(s). This message can
display when a device-level command is entered (e.g.,
show lpt config
).
When you change a bigger container, the value of smaller object is cleared. For example, originally the
operated object is Chassis=1, slot=4, L1AP=1 L2AP=2 L3D, and then when the command chassis 3 is
entered. This automatically sets the value of module, slot and port to 0.
If the value of module, slot and port are not set in later commands, and then you run a device-level
command (e.g.,
show lpt config
), this error message displays.
Enter the
go
command and be sure to include all of the location parameters.
Go [c=CHASSIS] [s=SLOT] [l1ap=L0APORT] [l2ap=L1APORT] (l1p=PORT|l2p=PORT|l3p=PORT|l1d|l2d|l3d)
System is initializing...
CLI is receiving continuous error message “
system is initializing...
”
1.
Wait for a few minutes for the message to clear.
2.
Cycle power to the IONMM.
3.
Retry the operation.
4.
If the problem persists, contact Technical Support.