D2
. Upgrade IONMM / NID Firmware from the
UPGRADE
Tab
1.
Access the IONMM card through the Web interface (see “Starting the Web Interface”).
2.
Select the
UPGRADE
tab.
3.
Select the
Firmware Database
sub-tab if not already selected.
4.
Locate the
Firmware Database Upload
section.
5.
Enter the
TFTP Server Address.
This is the IP address of the TFTP Server from step C (“Run TFTP
Server”) above.
6.
Enter the
Firmware File Name
. This is the name of the firmware file from step C sub-step 5
above.
7.
Click the
Upload
button.
The message “
The Firmware Database File is being transferred.
” Displays during the upload, and
the
Upload Result
area displays
In Progress
.
When successfully completed, the message “
Getting all records finished
” displays, the
Upload
Result
area displays “
Success
”, and the
Firmware Database Details
section displays updated
firmware information.
8.
If the firmware upload operation failed, the
Upload Result
area displays either:
•
None
: no operation was performed, or
•
Failure
: the specified operation has failed.
The
Upload Result
Reason
area displays a description of the cause of the upload ‘Failure’. This
area is blank if the
Upload Result
displayed is anything other than ‘Failure’.