Get SNMP version no such object.
You entered the CLI command to display SNMP configuration information, but it was not available. For
example:
C1|S3|L1D>
show snmp config
SNMP configuration:
Get SNMP version no such object.
C1|S3|L1D>
1.
Make sure this is the command / function that you wanted.
2.
Verify the command syntax. See “
Configuring SNMP
” .
3.
For complete command descriptions, see “
Command Line Interface (CLI) Reference
”.
4.
Try entering the command again. See “
DMI (Diagnostic Maintenance Interface) Parameters
”.
5.
If a problem persists, contact Technical Support.
Fail to set Ethernet port loopback operation, please check if Link OAM admin state of remote peer
port is enabled, link status and other issues
.
You entered the CLI command to define the type of Ethernet loopback test, but the command failed.
For example:
C1|S5|L1P2>
set oam loopback oper init
Fail to set Ethernet port loopback operation, please check if Link OAM admin state of remote peer port is
enabled, link status and other issues.
C1|S5|L1P2>
1.
Make sure the LOAM admin state of remote peer port is enabled (see “
set loam admin state
” com-
mand).
2.
Verify the command syntax.
3.
Use the
set oam loopback ?
command to display the card’s loopback capabilities. For example:
C1:S7:L1P1>
set oam loopback type ?
alternate
noloopback
remote
4.
Re-enter the
set oam loopback=
command with a loopback capability supported by the card.
5.
Verify the loopback capability with the
show oam loopback capability
command. For example:
C1|S5|L1P2>
show oam loopback capability
Loopback capability: alternate remotePeer
C1|S5|L1P2>
6.
Use another (supported) command, or use the go command to switch to a device that supports this
function.
7.
If the problem persists, contact Technical Support.