Message
:
The DMI feature is not supported on current port
Meaning
: Not all NID models support DMI. Lantronix NIDs that support DMI have a “D” at the end of the
model number. If you click the DMI tab on a NID model that does not support DMI, the message “
The
DMI feature is not supported on current port
.”
The DMI (Diagnostic Maintenance Interface) function displays NID diagnostic and maintenance
information such as interface characteristics, diagnostic monitoring parameters, and supported media
lengths.
Recovery
: 1. Verify that the device and port support DMI. See “
DMI (Diagnostic Maintenance Interface)
Parameters
” for more information.
2. Switch to a NID / port that supports the DMI feature.
3. Retry the operation.
Message
:
priority is empty or invalid
Meaning
: Can’t change ACL status to enable, message box show “priority is empty or invalid”
Recovery
: 1. Review the ACL entries. See “
Configuring an ACL
”.
3)
If the problem persists, contact Technical Support.
Message
:
Loading template config file succeeded
displays but the ION Stack node won’t expand.
Meaning
: Either the loading or the discovery process may be hung up.
Recovery
: 1. Click the checkbox to close the “
Loading, please wait ...
” dialog box (if displayed).
2. Contract and expand the ION Stack node again.
3. If the message “
Discovering succeeded
” displays, but the ION Stack node won’t expand:
a) Sign out and sign back in to the ION system
b) Cycle power to the ION system.
c) Disconnect and then re-connect the USB cable at the IONMM.
4.
If the problem persists, contact Technical Support.