Invalid input file
This message displays in the “
Upload Result Reason
” field at
IONMM
>
Upgrade
tab>
Firmware
database
sub-tab if the “Firmware File Name” entered had an incorrect filename format.
1.
Verify the parameter value entered; see “
Upgrading IONMM Firmware – Web Method
” for valid
input information.
2.
Retry the operation with a valid firmware file name (e.g.,
IONMM.bin.1.0.5
, or
x6010.bin.1.0.5
).
3.
If the problem persists, contact Technical Support.
Invalid input found!
This message indicates that you entered a parameter outside the valid range (e,g, VLAN ID = 0).
1.
Verify the parameter value to be entered; check the online Help for valid input information.
2.
Retry the operation.
3.
If the problem persists, contact Technical Support.
Invalid password!
This message indicates that the password entered during sign on is not valid.
1.
Sign in using the correct password. The default password is
private
.
Note:
the password is case sensitive.
Make sure the keyboard’s “Caps Lock” is off.
2.
Wait one to several minutes (how long depends on the population of the chassis) for the password
to be accepted and the log in to proceed.
3.
If the problem persists, contact Technical Support.
Failed to retrieve DMI info on current port.
You clicked the Device port’s DMI tab, but the device does not support DMI. Not all NID models/ports
support DMI. The NIDs that support DMI have a “D” at the end of the model number.
1.
Verify that the NID supports DMI.
2.
See “
DMI (Diagnostic Maintenance Interface) Parameters
” for more information.
3.
Retry the operation.
4.
If the problem persists, contact Technical Support.