Cannot access the NID via Telnet
1.
If you can access the IONMM, continue with step 2 below. If you cannot access the IONMM, see the
IONMM User Guide.
2.
Check that the syntax used for the
go
command is correct. The
go
command syntax is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
3.
Power cycle the NID.
4.
If the problem persists, contact Technical Support.
Cannot access the NID via the Web
1.
If you can access the IONMM, continue with step 2 below. If you cannot access the IONMM, see the
IONMM User Guide.
2.
Make sure that RADIUS client and HTTPS state are all set to disabled.
3.
Power cycle the NID.
4.
If the NID is a remote, power cycle the local NID.
5.
If the problem persists, contact Technical Support.
Cannot activate IP-based management
1.
Verify that the IP, gateway, and subnet mask are configured correctly.
2.
With DHCP enabled, DHCP could have failed leaving the system with the old static IP configuration.
Check the configuration via the USB port.
a)
Access the IONMM through a USB connection (see
“Starting a USB Session”
).
b)
At the command prompt, type:
show ip–129nter config
.
c)
Press
Enter
.
3.
If the problem persists, contact Technical Support.