Lantronix
ION x6010 User Guide
33493 Rev. F
Page 142 of 261
Fail to get MAC address!
This message indicates that communications to the module cannot be established.
1.
Verify that the correct hierarchy has been specified in the command (see
“Managing Slide-In and
Remote Modules Using CLI Commands”
).
2.
For all modules (slide-in and remote) check the following:
•
module is properly seated/connected
•
module is powered up
3.
Wait 60 seconds then retry the operation.
4.
Cycle power for the module in question.
Note:
for slide-in modules, pull the module out so it is no
longer connected to the backplane, then slide the module back in, ensuring that it is firmly seated.
5.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
6.
If the problem persists, contact Technical Support.
Fail to get port type!
This message indicates that a port level command was entered for the IONMM but the command is only
valid for the other types of slide-in modules.
1.
Use the
go
command to change location of where the command operates.
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.
Failed to set DHCP client state!
This message may indicate a problem in the IONMM DHCP setup / configuration.
1.
Verify the operation in the “
Assigning a Dynamic IP Address
” section of the IONMM User Guide.
2.
Retry the operation.
3.
If the problem persists, contact Technical Support.
Failed to set current time
Failed to set SNTP state!
Failed to set SNTP daylight savings time state!
Failed to set timezone!
Failed to set SNTP server
Failed to set SNTP server!
Failed to set system contact
Failed to set system name
Failed to set system location!
These messages indicate a problem in the IONMM SNTP setup / configuration.
1.
Verify the operation in the “
Configuring SNTP
” section of the IONMM User Guide.
2.
Retry the operation.
3.
If the problem persists, contact Technical Support.