Cannot get link pass through information on this card
This message indicates that a link pass through (LPT) CLI command was entered for an IONMM. CLI
commands for LPT operations are only valid for slide-in modules other than the IONMM. For example:
C1|S7|L1D>show lpt config
Cannot get link pass through information on this card!
C1|S7|L1D>
1.
Use the
go
command to change from the IONMM to the specific slide-in module. The
go
command
format is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.
Cannot get LOAM configuration on this port!
This message indicates that a port level command was entered for the IONMM but the command is only
valid for the other types of slide-in modules.
1.
Use the
go
command to change location of where the command operates. The
go
command format
is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.
Cannot get port security on this port!
This message indicates that a port level command was entered for the IONMM but the command is only
valid for the other types of slide-in modules.
1.
Use the
go
command to change location of where the command operates. The
go
command format
is:
go [c=CHASSIS] [s=SLOT] [l1ap=PORT] [l2ap=PORT] (l1p=PORT|l2p=PORT|l3p=
PORT|l1d|l2d|l3d)
2.
Retry the operation. See “
Section 6: Command Line Interface (CLI) Reference
”.
3.
If the problem persists, contact Technical Support.