Lantronix
ION x6010 User Guide
33493 Rev. F
Page 114 of 261
Command
:
TAOS Transmit Enable/Disable
Syntax
:
set taos transmit
=(enable|disable)
Description
:
A port-level command that defines the current x6010 port’s ability to send TAOS
(Transmit All OneS) signals. Defines the port’s ability to Transmit an All Ones pattern.
The default setting is enabled.
Example
:
C1|S4|L1D>
set taos ?
transmit
C1|S4|L1D>
set taos transmit ?
disable
enable
C1|S4|L1D>
set taos transmit enable
Error: this command should be executed on a port!
C1|S4|L1D>
go l1p=1
C1|S4|L1P1>
set taos transmit enable
C1|S4|L1P1>
go l1p=2
C1|S4|L1P2>
set taos transmit enable
C1|S4|L1P2>
Note
: Use the
show tdm port
config
command to display the current TAOS status.
Command
:
Show DMI Information
Syntax
:
show dmi info
<cr>
Description
:
Displays the Diagnostic Monitoring Interface (DMI) information (dmi table) for a fiber
port.
Example
:
Agent III C1|S2|L1P2>
show dmi info
Diagnostic monitoring interface information:
DMI connector type: LC
DMI indentifier: SFP
DMI Nominal bit rate: 1300*Mbps
DMI 9/125u Singlemode Fiber (m): N/A
DMI 50/125u Multimode Fiber (m): 500*m
DMI 62.5/125u Multimode Fiber (m): 30*10m
Copper(m): N/A
DMI fiber interface wavelength: 850*nm
DMI temperature: 40.8*C
DMI temperature: 105.4*F
DMI temperature alarm: normal
DMI transmit bias current: 4784*uA
DMI transmit bais alarm: normal
DMI Transmit power: 252*uW
DMI Transmit power: -5.986*dBM
DMI Transmit power alarm: normal
DMI Receive power: 242*uW
DMI Receive power: -6.162*dBM
DMI Receive power alarm: normal
DMI Receive power intrusion threshold: 0*uW
Agent III C1|S2|L1P2>