Device-Level Factory Defaults
Table 14: Device-Level Factory Defaults
Hardware Mode
System Level
Login / Password
ION / private
System Name
Device dependent (e.g., C6010-
3040)
Device Description
<null string>
TDM mode
Depends on DIP switch position
DIP switch 4-4, UP: T1, Down:E1
In-band Loopback
Selection
Depends on DIP switch position
DIP switch 3-4, UP: Disabled,
Down: Enabled.
Start Pattern: “11000”
Stop Pattern: “11100”
Port-Level Factory Defaults
Table 15: Port-Level Factory Defaults
Port 1
Circuit ID
<null string>
AIS Transmit
Depends on DIP switch position
DIP switch 4-1, UP: Disable,
Down: Enable
Transmit All Ones
Enabled
Long Haul
Depends on DIP switch position
Valid on T1 only
DIP switch 4-3, UP: No, Down: Yes
Line Build Out
Depends on TDM mode & DIP
switch position
See Table 17 below.
Loopback Type
Depends on front panel DIP
switch.
Switch 2, CL: PHY Layer,
Middle: No Loopback
Loopback Status
Depends on front panel DIP
switch.
Switch 2, CL: Local in Loopback,
Middle: No Loopback
Port 2
Circuit ID
<null string>
AIS Transmit
Depends on DIP switch position
DIP switch 4-2, UP: Disable,
Down: Enable
Transmit All Ones
Enabled
Loopback Type
Depends on front panel DIP
switch.
Switch 2, FL: PHY Layer,
Middle: No Loopback
Loopback Status
Depends on front panel DIP
switch.
Switch 2, FL: Local in Loopback,
Middle: No Loopback