10.
Note the
Long Haul
,
Line Build Out
and
Connector Type
field settings. Change the DIP switch
settings as required for your particular site configuration.
11.
Click the
Save
button at the bottom of the screen when done.
12.
Select
Port 2
.
13.
If required, enter a
Circuit ID
of up to 64 characters.
14.
In the
AIS Transmit
section select
Enabled
or
Disabled
.
15.
Note the
Alarm Indication Signal
field setting.
16.
Click the
Save
button at the bottom of the screen when done.
17.
Verify the x6010
Port 1
(copper port) configuration settings:
Circuit ID
– either blank or the information entered earlier displays (read/write field).
Link Status
– either
Down
or
Up
displayed (read only field).
AIS Transmit
– Select
Enabled
or
Disabled
as required (read/write field).
Transmit All Ones
– Displays the port’s TAOS status
Enabled
or
Disabled
(read only field).
Alarm Indication Signal
– When “
Alarm
” displays, the other end has TAOS enabled and is
currently transmitting an alarm condition. When “
Normal
” displays, there is no alarm (read only
field).
Long Haul
– Indicates the current position of the remote device’s Short/Long haul configuration
switch (read only field, e.g.,
Yes
or
No
).