Web UI Management connection Lost
1.
With the “Egress Rate Limit” set to “Unlimited”, the PC can ping the device (e.g., S2220-1013).
2.
After reducing the “Egress Rate Limit” to “80m”, the ping fails.
The return traffic to the PC is non-mgmt packet and is subjected to Egress rate-limiting, hence these
packets are getting dropped.
3.
Increase the port 1 “Egress Rate Limit” to “900m” or “800m” to reserve some Egress bandwidth for
user management traffic.
The PC can ping to S2220-1013 again, and the WEB UI can be managed again.