TDM Mode Configuration
The x6010 is shipped from the factory in T1 mode. Use the procedure below to configure E1 mode.
You can configure E1 mode via either the CLI or the Web interface.
Configuring TDM Mode – CLI Method
1.
Set DIP Switch SW4 switch #4 to the Down position. See “
DIP Switches
”.
2.
Install the x6010 as described in “
Section 2: Installation and System Setup
”
.
3.
Access the x6010 through either a USB connection (see “
Starting a USB Session
”) or a Telnet session
(see “
Starting a Telnet Session
”
).
4.
At the x6010 CLI command prompt, use the
go
command to switch to Port 1.
Type
go c
=1
s
=
x
l1p
=1 and press
Enter
(where x is the x6010 slot location in the ION chassis).
5.
If required, enter a Circuit ID of up to 64 characters using the
set circuit-ID
command.
6.
Configure the Loopback Management section as required using the
set tdm loopback oper
and the
set tdm loopback oper type
commands.
7.
Configure TAOS Transmit. Type
set taos transmit
={disable|enable} and press
Enter
.
8.
Verify the E1 mode configuration. For example:
C1|S4|L1D>
show tdm config
tdm type: e1
C1|S4|L1D>
go l1p=1
C1|S4|L1P1>
set tdm loopback type phylayer
C1|S4|L1P1>
show tdm ?
config
loopback
port
C1|S4|L1P1>
show tdm port config
link oper status: up
alarm indication signal: normal
taos transmit: enabled
lbo status: e13-0V120ohm
longhaul: no
connector: Dual BNC
C1|S4|L1P1>
C1|S4|L1D>
go l1p=2
C1|S4|L1P2>
show tdm port config
link oper status: down
alarm indication signal: normal
taos transmit: enabled
connector: SFP Slot
C1|S4|L1P2>