Lantronix
ION x6010 User Guide
33493 Rev. F
Page 233 of 261
Message
: Invalid location parameters, cannot find the physical entity
!
Meaning
: 1) The
go
command you entered includes a location that does not exist or that you entered
incorrectly. 2) The NID is in the process of a reset operation; wait one minute and then re-try the func-
tion.
Recovery
:
1.
Run the
stat
command to verify your configuration.
2.
Click the plus sign [
+
] next to
ION Stack
to unfold the “ION Stack” node in the left tree view to
refresh device status.
3.
Click the plus sign [+] next to
Chassis
to unfold the chassis devices.
4.
Compare the
stat
command results to the Web interface tree view configuration information.
5.
Re-run the
stat
command with the correct location parameters.
6.
Ping the device in question.
7.
Unplug and re-plug the USB connector on the IONMM card.
8.
If the problem persists, contact Technical Support.
Message
:
Unknown command
!
Meaning
: The command you entered is not supported, or you entered the wrong command
format / syntax.
Recovery
:
1.
Verify the CLI command syntax.
2.
See “
Section 6: Command Line Interface (CLI) Reference
”.