11.
A table of available modules displays with upgrade instructions.
C1|S7|L1D>upgrade module
Available modules:
index module loc
1 ION219 c=1 s=0 l1d
2 C3230-1040 c=1 s=3 l1d
3 C3230-1040 c=1 s=5 l1d
4 S3230-1040 c=1 s=5 l1ap=2 l2d
5 IONMM c=1 s=7 l1d
6 C3231-1040 c=1 s=10 l1d
7 C2110-1013 c=1 s=12 l1d
8 C2210-1013 c=1 s=13 l1d
9 C2220-1014 c=1 s=16 l1d
10 C3220-1040 c=1 s=18 l1d
11 IONPS-A c=1 s=22 l1d
Choose the module you want to upgrade: (eg. 1,3,16; at most 8 modules to
upgrade, press ‘q’ to exit upgrade)
1,2,3,4,5,6,10,11
It may take some time to finish the task, you can continue with other works,
then use “show firmware upgrade result” to check result.
12.
Choose the module(s) to upgrade (#
1-6,10,11
in the example above) and press
Enter
.
13.
Verify the Upgrade results. Type
show firmware upgrade result
and press
Enter
.
The firmware upgrade results are displayed in a table. If the firmware upgrade was successful,
the
time started
and
time completed
display.
C1|S7|L1D>
show firmware upgrade result
index module status reason time started time completed
1 card registering... success 00:21:23 00:21:32
2 C3230-1040 c=1 s=3 l1d inProgress 00:21:23 00:00:00
3 C3230-1040 c=1 s=5 l1d inProgress 00:21:24 00:00:00
4 S3230-1040 c=1 s=5 l1ap=2 l2d inProgress 00:21:24 00:00:00
5 IONMM c=1 s=7 l1d success 00:21:24 00:21:47
6 C3231-1040 c=1 s=10 l1d inProgress 00:21:26 00:00:00
7 C3220-1040 c=1 s=18 l1d inProgress 00:21:26 00:00:00
8 IONPS-A c=1 s=22 l1d success 00:21:29 00:21:40
C1|S7|L1D>
If a module upgrade was unsuccessful, the reason for the failure displays in the “reason” column
of the table (e.g.,
invalid input file
,
protocol timeout
). See “
Section 5 – Troubleshooting
” for
error messages and recovery procedures.