7.3 List of Fault, Minor Fault, Alarm, and Error Codes
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
313
Display (Hex.)
Name
ALM LED
Type
Ref.
EP24v (0081)
External Power 24V Supply
Flashing
An alarm
Er-01
Motor Data Error
Flashing
An Auto-Tuning Error
Er-02
Drive in an Alarm State
Flashing
An Auto-Tuning Error
Er-03
STOP Button was Pressed
Flashing
An Auto-Tuning Error
Er-04
Line-to-Line Resistance Error
Flashing
An Auto-Tuning Error
Er-05
No-Load Current Error
Flashing
An Auto-Tuning Error
Er-08
Rated Slip Error
Flashing
An Auto-Tuning Error
Er-09
Acceleration Error
Flashing
An Auto-Tuning Error
Er-10
Motor Direction Error
Flashing
An Auto-Tuning Error
Er-11
Motor Speed Error
Flashing
An Auto-Tuning Error
Er-12
Current Detection Error
Flashing
An Auto-Tuning Error
Er-13
Leakage Inductance Error
Flashing
An Auto-Tuning Error
Er-14
Motor Speed Error 2
Flashing
An Auto-Tuning Error
Er-15
Torque Saturation Error
Flashing
An Auto-Tuning Error
Er-16
Inertia ID Error
Flashing
An Auto-Tuning Error
Er-17
Reverse Prohibited Error
Flashing
An Auto-Tuning Error
Er-18
Back EMF Error
Flashing
An Auto-Tuning Error
Er-19
PM Inductance Error
Flashing
An Auto-Tuning Error
Er-20
Stator Resistance Error
Flashing
An Auto-Tuning Error
Er-21
Z Pulse Correction Error
Flashing
An Auto-Tuning Error
Er-25
HighFreq Inject Param Tuning Err
Flashing
An Auto-Tuning Error
Err (001F)
EEPROM Write Error
Illuminated
Faults
FAn1 (0413)
Drive Cooling Fan Fault
Illuminated
Faults
FbH (0028)
Excessive PID Feedback
Flashing
Alarm
FbH (0041)
Excessive PID Feedback
Illuminated
Faults
FbL (0027)
PID Feedback Loss
Flashing
Alarm
FbL (0028)
PID Feedback Loss
Illuminated
Faults
GF (0006)
Ground Fault
Illuminated
Faults
HCA (0034)
High Current Alarm
Flashing
Alarm
HLCE
High Level Communication Errors
Illuminated
Faults
iFEr
Communication Err
-
Backup Function Runtime Errors
L24v (0021)
Loss of External Power 24 Supply
Flashing
An alarm
LF (001C)
Output Phase Loss
Illuminated
Faults
LF2 (0036)
Output Current Imbalance
Illuminated
Faults
LoG
Log Com Error
Flashing
An alarm
LSo (0051)
Low Speed Motor Step-Out
Illuminated
Faults
LT-1 (0035)
Cooling Fan Maintenance Time
Flashing
An alarm
LT-2 (0036)
Capacitor Maintenance Time
Flashing
An alarm
LT-3 (0043)
SoftChargeBypassRelay MainteTime
Flashing
An alarm
LT-4 (0044)
IGBT Maintenance Time (50%)
Flashing
An alarm
ndAT
Model,VolClass,Capacity Mismatch
-
Backup Function Runtime Errors
nSE (0052)
Node Setup Error
Illuminated
Faults
oC (0007)
Overcurrent
Illuminated
Faults
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...