320
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
Code
Name
Causes
Possible Solutions
dv2
Z Pulse Noise Fault Detection
Noise interference along the encoder cable.
Isolate the encoder cable from the drive output line or a different
source of electrical interference.
The encoder cable is disconnected or wired
incorrectly.
Examine for wiring errors or disconnected wires in the encoder
cable, and repair problems. Correctly ground the shielded wire of
the encoder cable.
The drive is operating a motor with 24 or more poles
at zero speed.
•
Set
F1-46 = 1 [dv2 Detection Method Selection =
MechanicalAngle Detection Method]
.
•
Increase
F1-17 [Deviation 2 Detection Selection]
.
•
Increase
F1-47 [Deviation 2 Detection Level]
.
Note:
If you change the setting of
F1-47
, the sensitivity of detection
for
dv2
can decrease.
The PG option or the encoder on the motor side is
damaged.
Repair the wiring and re-energize the drive, then replace the PG
option or the encoder if the problem continues.
Note:
•
The drive detects this error if it detects more than one Z pulse per rotation for the number of rotations set in
F1-17 [Deviation 2 Detection Selection]
.
•
Do a Fault Reset to clear the fault.
Code
Name
Causes
Possible Solutions
dv3
Inversion Detection
E5-11 [Encoder Z-Pulse Offset]
is set incorrectly.
Correctly set the value for Δθ to
E5-11
as specified by the values on
the motor nameplate.
There is a new encoder or the motor rotation direction
changed.
Do Z Pulse Offset Tuning.
An external force on the load side rotated the motor.
•
Make sure that the motor is rotating in the correct direction.
•
Find and repair problems on the load side that cause the motor to
rotate from the load side.
Noise interference along the encoder cable.
Correctly ground the shielded wire of the encoder cable.
The encoder cable is disconnected or wired
incorrectly.
Examine for wiring errors or disconnected wires in the encoder
cable, and repair problems.
The setting for
F1-05 [Encoder 1 Rotation Selection]
is the opposite of the direction of motor rotation.
Correctly connect the motor wiring for each phase (U, V, W).
The drive incorrectly detected the motor magnetic
pole position.
If the value for
U6-57 [PolePolarityDeterVal]
is lower than 819,
increase the value set in
n8-84 [Polarity Detection Current]
.
Contact the motor manufacturer to confirm the maximum setting
values.
The setting value of
n8-84 [Polarity Detection
Current]
is too low.
Increase the value set in
n8-84
from the default setting. Contact the
motor manufacturer to confirm the maximum setting values.
The drive did not make a correct estimate of the
initial pole count.
When you use an IPM motor, do High Frequency Injection Auto-
Tuning.
The PG option card or the encoder on the motor side
is damaged.
Repair the wiring and re-energize the drive, then replace the PG
option card or the encoder if the problem continues.
Note:
•
The drive detects this error if:
–
the torque reference and acceleration are in opposite directions.
–
the speed reference and actual motor speed are more than 30% different for the number of times set to
F1-18 [Deviation 3 Detection Selection]
.
•
Do a Fault Reset to clear the fault.
Code
Name
Causes
Possible Solutions
dv4
Inversion Prevention Detection
An external force on the load side rotated the motor.
•
Make sure that the motor is rotating in the correct direction.
•
Find and repair problems on the load side that cause the motor to
rotate from the load side.
•
Disable detection of this fault for applications that rotate the
motor from the load side in the opposite direction of the speed
reference. The drive will not detect this fault if
F1-19 = 0
[Deviation 4 Detection Selection = Disabled]
.
E5-11 [Encoder Z-Pulse Offset]
is set incorrectly.
Correctly set the value for Δθ to
E5-11
as specified by the values on
the motor nameplate.
There is a new encoder or the motor rotation direction
changed.
Do Z Pulse Offset Tuning.
Noise interference along the encoder cable.
Correctly ground the shielded wire of the encoder cable.
The encoder cable is disconnected or wired
incorrectly.
Examine for wiring errors or disconnected wires in the encoder
cable, and repair problems.
The drive incorrectly detected the motor magnetic
pole position.
If the value for
U6-57 [PolePolarityDeterVal]
is lower than 819,
increase the value set in
n8-84 [Polarity Detection Current]
.
Consult the motor manufacturer for information about maximum
setting values.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...