SIEPC71061737B GA800 Drive Technical Reference
3 : 5 Mbps
4 : 10 Mbps
■
F6-14: BUS Error Auto Reset
No.
(Hex.)
Name
Description
Default
(Range)
F6-14
(03BB)
BUS Error Auto Reset
Sets the automatic reset function for
bUS [Option Communication Errors]
.
0
(0, 1)
0 : Disabled
1 : Enabled
■
F6-15: Comm. Option Parameters Reload
No.
(Hex.)
Name
Description
Default
(Range)
F6-15
(0B5B)
Comm. Option Parameters
Reload
Sets the update method when you change
F6-xx, F7-xx [Communication Options]
.
0
(0 - 2)
Note:
•
Set
F6-15 = 0, 1
to reload
F6-xx
,
F7-xx
.
•
Set
F6-15 = 0, 1
to reset the display on the keypad to
0
.
0 : Reload at Next Power Cycle
Restart the drive to update parameters.
1 : Reload Now
The changed parameters are updated without restarting the drive.
2 : Cancel Reload Request
Cancels
CyPo [Cycle Power to Accept Changes]
.
■
F6-16: Gateway Mode
No.
(Hex.)
Name
Description
Default
(Range)
F6-16
(0B8A)
Gateway Mode
Sets the gateway mode operation and the number of connected slave drives.
0
(0 to 4)
0 : Disabled
1 : Enabled: 1 Slave Drives
2 : Enabled: 2 Slave Drives
3 : Enabled: 3 Slave Drives
4 : Enabled: 4 Slave Drives
■
F6-20: MECHATROLINK Station Address
No.
(Hex.)
Name
Description
Default
(Range)
F6-20
(036B)
MECHATROLINK Station
Address
Sets the station address for MECHATROLINK communication. Restart the drive after you change
the parameter setting.
0021h
(MECHATROLINK-II:
0020h - 003Fh,
MECHATROLINK-III:
0003h - 00EFh)
Note:
•
The setting range changes if using MECHATROLINK-II or MECHATROLINK-III:
–
MECHATROLINK-II (SI-T3) range: 20 to 3F
–
MECHATROLINK-III (SI-ET3) range: 03 to EF
•
Be sure to set a node address that is different than all other node addresses. Incorrect parameter settings will cause
AEr [Station Address
Setting Error]
errors and the L.ERR LED on the option will come on.
•
The drive detects
AEr
errors when the station address is 20 or 3F.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...