11.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
593
No.
Name
Range
Unit
Control Method (A1-02 Setting)
OLV/PM
(5)
AOLV/PM
(6)
CLV/PM
(7)
EZOLV
(8)
b6-03
Dwell Reference at Stop 0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
b8-02
Energy Saving Gain
0.0 - 10.0
0.1
-
-
-
-
b8-03
Energy Saving Filter
Time
0.00 - 10.00
0.01 s
-
-
-
-
b8-19
E-Save Search Injection
Freq
10 - 300
1 Hz
-
100
100
20
C1-11
Accel/Decel Time
Switchover Freq
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
C2-01
S-Curve Time @ Start
of Accel
0.00 - 10.00
0.01 s
1.00
0.20
0.20
1.00
C3-01
Slip Compensation Gain 0.0 - 2.5
0.1
-
-
-
0.0
C3-02
Slip Compensation
Delay Time
0 - 10000
1 ms
-
-
-
200
C4-01
Torque Compensation
Gain
0.00 - 2.50
0.01
0.00
-
-
0.00
C4-02
Torque Compensation
Delay Time
0 - 60000
1 ms
100
-
-
200
C5-01
ASR Proportional Gain
1
0.00 - 300.00
0.01
-
10.00
20.00
10.00
C5-02
ASR Integral Time 1
0.000 - 60.000
0.001 s
-
0.500
0.500
0.500
C5-03
ASR Proportional Gain
2
0.00 - 300.00
0.01
-
10.00
20.00
10.00
C5-04
ASR Integral Time 2
0.000 - 60.000
0.001 s
-
0.500
0.500
0.500
C5-06
ASR Delay Time
0.000 - 0.500
0.001 s
-
0.016
0.004
0.004
C5-07
ASR Gain Switchover
Frequency
0.0 - 400.0
0.1
-
0.0%
0.0%
0.0 Hz
C6-02
Carrier Frequency
Selection
1 - F
1
2
2
2
2
d3-01
Jump Frequency 1
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-02
Jump Frequency 2
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-03
Jump Frequency 3
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-04
Jump Frequency Width
0.0 - 20.0
0.1
1.0 Hz
1.0%
1.0%
1.0 Hz
d5-02
Torque Reference Delay
Time
0 - 1000
1 ms
-
0
0
-
E1-04
Maximum Output
Frequency
40.0 - 400.0
0.1 Hz
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-05
Maximum Output
Voltage
0.0 - 255.0
0.1 V
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-06
Base Frequency
0.0 - 400.0
0.1 Hz
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-07
Mid Point A Frequency
0.0 - 400.0
0.1 Hz
-
-
-
-
E1-08
Mid Point A Voltage
0.0 - 255.0
0.1 V
-
-
-
-
E1-09
Minimum Output
Frequency
0.0 - 400.0
0.1 Hz
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-10
Minimum Output
Voltage
0.0 - 255.0
0.1 V
-
-
-
-
F1-01
Encoder 1 Pulse Count
(PPR)
0 - 60000
1 ppr
-
-
1024
-
F1-05
Encoder 1 Rotation
Selection
0 - 1
1
-
-
1
-
F1-09
Overspeed Detection
Delay Time
0.0 - 2.0
0.1 s
-
0.0
0.0
0.0
L1-01
Motor Overload (oL1)
Protection
0 - 6
1
4
4
5
1
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...