11.22 Parameters Changed by PM Motor Code Selection
622
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-03
PM Motor Rated Current
(FLA)
A
0.94
1.56
2.81
4.27
6.98
10.21
13.85
19.5
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
12.760
7.421
4.825
2.656
1.353
0.999
0.713
0.393
E5-06
PM d-axis Inductance
(mH/phase)
mH
128.60
85.11
58.87
46.42
31.73
26.20
27.06
15.51
E5-07
PM q-axis Inductance
(mH/phase)
mH
166.96
113.19
80.59
60.32
40.45
30.94
33.45
19.63
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad
528.6
544.2
568.5
572.8
562.9
587.6
670.1
612.7
E5-24
PM Back-EMF L-L
Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output
Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output
Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.0017
0.0023
0.0043
0.0083
0.0136
0.017
0.027
0.046
L3-24
Motor Accel Time @
Rated Torque
s
0.098
0.071
0.066
0.087
0.085
0.072
0.084
0.096
n5-02
Motor Inertia
Acceleration Time
s
0.098
0.071
0.066
0.087
0.085
0.072
0.084
0.096
n8-49
Heavy Load Id Current
%
-6.6
-9.2
-13.5
-12.1
-13.7
-10.1
-12.2
-15.5
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 11.14 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
133E
133F
1340
1342
1343
1344
1345
Voltage Class
V
400
400
400
400
400
400
400
Capacity
kW
15
18
22
30
37
45
55
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
15
18.50
22.00
30.00
37.00
45.00
55.00
E5-03
PM Motor Rated Current
(FLA)
A
27.4
32.9
37.6
52.5
63.2
76.4
96.1
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
0.295
0.223
0.164
0.137
0.093
0.059
0.048
E5-06
PM d-axis Inductance (mH/
phase)
mH
12.65
9.87
7.90
7.01
5.93
4.17
3.11
E5-07
PM q-axis Inductance (mH/
phase)
mH
15.87
12.40
10.38
8.68
6.79
5.22
4.55
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad
624.6
610.4
655.4
708.4
739.2
703.0
747.1
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output
Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.055
0.064
0.116
0.140
0.259
0.312
0.42
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...