11.22 Parameters Changed by PM Motor Code Selection
616
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
11.22 Parameters Changed by PM Motor Code Selection
Note:
The motor codes listed in these tables are the only correct setting values.
◆
Yaskawa SMRA Series SPM Motors
Table 11.4 SMRA series motor code setting for specification of 200 V at 1800 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
0002
0003
0005
0006
0008
Voltage Class
V
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
Motor Rotation Speed
min
-1
1800
1800
1800
1800
1800
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
E5-03
PM Motor Rated Current
(FLA)
A
2.1
4.0
6.9
10.8
17.4
E5-04
PM Motor Pole Count
-
8
8
8
8
8
E5-05
PM Motor Resistance (ohms/
phase)
Ω
2.47
1.02
0.679
0.291
0.169
E5-06
PM d-axis Inductance (mH/
phase)
mH
12.7
4.8
3.9
3.6
2.5
E5-07
PM q-axis Inductance (mH/
phase)
mH
12.7
4.8
3.9
3.6
2.5
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad
0
0
0
0
0
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
62.0
64.1
73.4
69.6
72.2
E1-04
Maximum Output Frequency
Hz
120
120
120
120
120
E1-05
Maximum Output Voltage
V
200.0
200.0
200.0
200.0
200.0
E1-06
Base Frequency
Hz
120
120
120
120
120
E1-09
Minimum Output Frequency
Hz
6
6
6
6
6
C5-17
Motor Inertia
kgm
2
0.0007
0.0014
0.0021
0.0032
0.0046
L3-24
Motor Accel Time @ Rated
Torque
s
0.064
0.066
0.049
0.051
0.044
n5-02
Motor Inertia Acceleration
Time
s
0.064
0.066
0.049
0.051
0.044
n8-49
Heavy Load Id Current
%
0
0
0
0
0
Table 11.5 SMRA Series Motor Code Setting for Specification of 200 V at 3600 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
0103
0105
0106
0108
Voltage Class
V
200
200
200
200
Capacity
kW
0.75
1.5
2.2
3.7
Motor Rotation Speed
min
-1
3600
3600
3600
3600
E5-02
PM Motor Rated Power
kW
0.75
1.5
2.2
3.7
E5-03
PM Motor Rated Current
(FLA)
A
4.1
8.0
10.5
16.5
E5-04
PM Motor Pole Count
-
8
8
8
8
E5-05
PM Motor Resistance (ohms/
phase)
Ω
0.538
0.20
0.15
0.097
E5-06
PM d-axis Inductance (mH/
phase)
mH
3.2
1.3
1.1
1.1
E5-07
PM q-axis Inductance (mH/
phase)
mH
3.2
1.3
1.1
1.1
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...